Quantitative Detection of House Dust Mites-Specific IgE by Light-Initiated Chemiluminescence Assay.

Xiaohui Yang, Lisheng Zheng, Yuanmin Sun, Xin Tan, Bei Zhang, Xue Li, Huiqiang Li
{"title":"Quantitative Detection of House Dust Mites-Specific IgE by Light-Initiated Chemiluminescence Assay.","authors":"Xiaohui Yang, Lisheng Zheng, Yuanmin Sun, Xin Tan, Bei Zhang, Xue Li, Huiqiang Li","doi":"10.1093/labmed/lmad024","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To establish a new method for quantitative detection of house dust mite (HDM)-sIgE based on light-initiated chemiluminescence assay (LiCA).</p><p><strong>Methods: </strong>The assay was established after optimizing the reaction conditions, and the assay performance was evaluated according to the clinical guidelines. Further, the results of LiCA were compared with those from the ELISA and ImmunoCAP methods.</p><p><strong>Results: </strong>Coefficients of variation for repeatability ranged from 4.22% to 7.69%, and intermediate precision from 8.38% to 10.34%. The limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were 0.066 kUA/L, 0.165 kUA/L, and 0.171 kUA/L, respectively. The coefficient of correlation (r) between the results of LiCA and ELISA was 0.9263, and the r between the results of LiCA and ImmunoCAP was 0.8870.</p><p><strong>Conclusions: </strong>A HDM-sIgE quantitation assay based on LiCA was established, which could be used as a new reliable analytical tool for the determination of HDM-sIgE.</p>","PeriodicalId":17951,"journal":{"name":"Laboratory medicine","volume":" ","pages":"27-33"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/labmed/lmad024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To establish a new method for quantitative detection of house dust mite (HDM)-sIgE based on light-initiated chemiluminescence assay (LiCA).

Methods: The assay was established after optimizing the reaction conditions, and the assay performance was evaluated according to the clinical guidelines. Further, the results of LiCA were compared with those from the ELISA and ImmunoCAP methods.

Results: Coefficients of variation for repeatability ranged from 4.22% to 7.69%, and intermediate precision from 8.38% to 10.34%. The limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were 0.066 kUA/L, 0.165 kUA/L, and 0.171 kUA/L, respectively. The coefficient of correlation (r) between the results of LiCA and ELISA was 0.9263, and the r between the results of LiCA and ImmunoCAP was 0.8870.

Conclusions: A HDM-sIgE quantitation assay based on LiCA was established, which could be used as a new reliable analytical tool for the determination of HDM-sIgE.

用光引发化学发光测定法定量检测屋尘螨特异性 IgE
摘要建立一种基于光引发化学发光法(LiCA)的屋尘螨sIgE定量检测新方法:方法:在优化反应条件后建立了该检测方法,并根据临床指南对检测性能进行了评估。此外,还将 LiCA 的结果与 ELISA 和 ImmunoCAP 方法的结果进行了比较:重复性变异系数为 4.22% 至 7.69%,中间精度为 8.38% 至 10.34%。空白限(LoB)、检出限(LoD)和定量限(LoQ)分别为 0.066 kUA/L、0.165 kUA/L 和 0.171 kUA/L。LiCA结果与ELISA结果的相关系数(r)为0.9263,LiCA结果与ImmunoCAP结果的相关系数(r)为0.8870:结论:建立了一种基于 LiCA 的 HDM-sIgE 定量分析方法,它可作为一种新的可靠的分析工具用于测定 HDM-sIgE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信