Free thyroxine measurement in clinical practice: how to optimize indications, analytical procedures, and interpretation criteria while waiting for global standardization.
Federica D'Aurizio, Jürgen Kratzsch, Damien Gruson, Petra Petranović Ovčariček, Luca Giovanella
{"title":"Free thyroxine measurement in clinical practice: how to optimize indications, analytical procedures, and interpretation criteria while waiting for global standardization.","authors":"Federica D'Aurizio, Jürgen Kratzsch, Damien Gruson, Petra Petranović Ovčariček, Luca Giovanella","doi":"10.1080/10408363.2022.2121960","DOIUrl":null,"url":null,"abstract":"<p><p>Thyroid dysfunctions are among the most common endocrine disorders and accurate biochemical testing is needed to confirm or rule out a diagnosis. Notably, true hyperthyroidism and hypothyroidism in the setting of a normal thyroid-stimulating hormone level are highly unlikely, making the assessment of free thyroxine (FT4) inappropriate in most new cases. However, FT4 measurement is integral in both the diagnosis and management of relevant central dysfunctions (central hypothyroidism and central hyperthyroidism) as well as for monitoring therapy in hyperthyroid patients treated with anti-thyroid drugs or radioiodine. In such settings, accurate FT4 quantification is required. Global standardization will improve the comparability of the results across laboratories and allow the development of common clinical decision limits in evidence-based guidelines. The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests has undertaken FT4 immunoassay method comparison and recalibration studies and developed a reference measurement procedure that is currently being validated. However, technical and implementation challenges, including the establishment of different clinical decision limits for distinct patient groups, still remain. Accordingly, different assays and reference values cannot be interchanged. Two-way communication between the laboratory and clinical specialists is pivotal to properly select a reliable FT4 assay, establish reference intervals, investigate discordant results, and monitor the analytical and clinical performance of the method over time.</p>","PeriodicalId":10760,"journal":{"name":"Critical reviews in clinical laboratory sciences","volume":"60 2","pages":"101-140"},"PeriodicalIF":6.6000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical reviews in clinical laboratory sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/10408363.2022.2121960","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 4
Abstract
Thyroid dysfunctions are among the most common endocrine disorders and accurate biochemical testing is needed to confirm or rule out a diagnosis. Notably, true hyperthyroidism and hypothyroidism in the setting of a normal thyroid-stimulating hormone level are highly unlikely, making the assessment of free thyroxine (FT4) inappropriate in most new cases. However, FT4 measurement is integral in both the diagnosis and management of relevant central dysfunctions (central hypothyroidism and central hyperthyroidism) as well as for monitoring therapy in hyperthyroid patients treated with anti-thyroid drugs or radioiodine. In such settings, accurate FT4 quantification is required. Global standardization will improve the comparability of the results across laboratories and allow the development of common clinical decision limits in evidence-based guidelines. The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests has undertaken FT4 immunoassay method comparison and recalibration studies and developed a reference measurement procedure that is currently being validated. However, technical and implementation challenges, including the establishment of different clinical decision limits for distinct patient groups, still remain. Accordingly, different assays and reference values cannot be interchanged. Two-way communication between the laboratory and clinical specialists is pivotal to properly select a reliable FT4 assay, establish reference intervals, investigate discordant results, and monitor the analytical and clinical performance of the method over time.
期刊介绍:
Critical Reviews in Clinical Laboratory Sciences publishes comprehensive and high quality review articles in all areas of clinical laboratory science, including clinical biochemistry, hematology, microbiology, pathology, transfusion medicine, genetics, immunology and molecular diagnostics. The reviews critically evaluate the status of current issues in the selected areas, with a focus on clinical laboratory diagnostics and latest advances. The adjective “critical” implies a balanced synthesis of results and conclusions that are frequently contradictory and controversial.