Tomographic 3D ultrasound for grading stenosis of superficial femoral artery.

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Perfusion-Uk Pub Date : 2024-07-01 Epub Date: 2023-04-17 DOI:10.1177/02676591231169852
Adel Alzahrani, Salahaden R Sultan, Mohammed Aslam
{"title":"Tomographic 3D ultrasound for grading stenosis of superficial femoral artery.","authors":"Adel Alzahrani, Salahaden R Sultan, Mohammed Aslam","doi":"10.1177/02676591231169852","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Treatment decision of lower extremity peripheral arterial disease (PAD) is governed by the severity of stenosis. Tomographic 3D ultrasound (t3DUS) is a reliable imaging technique for measuring vessel stenosis. In this study we attempted to provide a precise measurement of superficial femoral artery (SFA) stenosis using t3DUS in patients with PAD.</p><p><strong>Methods: </strong>t3DUS was used to measure maximum stenosis percentage in SFA from 50 patients with lower extremity PAD. The maximum stenosed segment in SFA was defined using Duplex 2DUS aliasing was noted. The peak systolic velocity (PSV) was measured at the maximum stenotic site and proximal to aliasing for calculating the velocity ratio. The association between blood flow velocity ratio and the degree of stenosis measured using Duplex 2DUS and t3DUS, respectively, was assessed using Spearman rank correlation.</p><p><strong>Results: </strong>There was a strong positive correlation between velocity ratio and degree of stenosis in SFA measured using t3DUS (correlation value <i>(r)</i> = 0.99, <i>p</i> < 0.001). The correlation between Stenosis percentage and velocity ratio in SFA are as followed: <50:<2; 50-54:2-2.4; 55-59:2.5-2.9; 60-64:3-3.4; 65-69:3.5-3.9; 70-74:4-4.4; 75-79:4.5-4.9; >80:>5.</p><p><p>t3DUS can be used to provide precise measurement of the severity of SFA stenosis in patients with lower extremities arterial disease. The established criteria for grading SFA stenosis in this study can be applied to the current practice alongside Duplex 2DUS as it showed a strong positive correlation with velocity ratio. Further studies investigating the sensitivity and specificity of t3DUS in the assessment of stenosis in lower limbs arteries are required.</p>","PeriodicalId":49707,"journal":{"name":"Perfusion-Uk","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perfusion-Uk","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02676591231169852","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/17 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Treatment decision of lower extremity peripheral arterial disease (PAD) is governed by the severity of stenosis. Tomographic 3D ultrasound (t3DUS) is a reliable imaging technique for measuring vessel stenosis. In this study we attempted to provide a precise measurement of superficial femoral artery (SFA) stenosis using t3DUS in patients with PAD.

Methods: t3DUS was used to measure maximum stenosis percentage in SFA from 50 patients with lower extremity PAD. The maximum stenosed segment in SFA was defined using Duplex 2DUS aliasing was noted. The peak systolic velocity (PSV) was measured at the maximum stenotic site and proximal to aliasing for calculating the velocity ratio. The association between blood flow velocity ratio and the degree of stenosis measured using Duplex 2DUS and t3DUS, respectively, was assessed using Spearman rank correlation.

Results: There was a strong positive correlation between velocity ratio and degree of stenosis in SFA measured using t3DUS (correlation value (r) = 0.99, p < 0.001). The correlation between Stenosis percentage and velocity ratio in SFA are as followed: <50:<2; 50-54:2-2.4; 55-59:2.5-2.9; 60-64:3-3.4; 65-69:3.5-3.9; 70-74:4-4.4; 75-79:4.5-4.9; >80:>5.

t3DUS can be used to provide precise measurement of the severity of SFA stenosis in patients with lower extremities arterial disease. The established criteria for grading SFA stenosis in this study can be applied to the current practice alongside Duplex 2DUS as it showed a strong positive correlation with velocity ratio. Further studies investigating the sensitivity and specificity of t3DUS in the assessment of stenosis in lower limbs arteries are required.

用于股浅动脉狭窄分级的断层 3D 超声波。
简介:下肢外周动脉疾病(PAD)的治疗决策取决于血管狭窄的严重程度。断层三维超声(t3DUS)是测量血管狭窄程度的可靠成像技术。在这项研究中,我们尝试使用 t3DUS 对 PAD 患者的股浅动脉 (SFA) 狭窄程度进行精确测量。方法:使用 t3DUS 测量 50 名下肢 PAD 患者的 SFA 最大狭窄率。在最大狭窄部位和别离近端测量收缩峰值速度(PSV)以计算速度比。使用斯皮尔曼秩相关法评估了血流速度比与分别使用双相二维超声和三维超声测量的狭窄程度之间的关系:结果:使用 t3DUS 测量的速度比与 SFA 狭窄程度之间存在很强的正相关性(相关值 (r) = 0.99,p < 0.001)。SFA 狭窄百分比与速度比之间的相关性如下:t3DUS可用于精确测量下肢动脉疾病患者的SFA狭窄严重程度。这项研究中确定的 SFA 狭窄分级标准可与双相 2DUS 一起应用于当前的实践中,因为它与速度比值显示出很强的正相关性。还需要进一步研究 t3DUS 在评估下肢动脉狭窄方面的敏感性和特异性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Perfusion-Uk
Perfusion-Uk 医学-外周血管病
CiteScore
3.00
自引率
8.30%
发文量
203
审稿时长
6-12 weeks
期刊介绍: Perfusion is an ISI-ranked, peer-reviewed scholarly journal, which provides current information on all aspects of perfusion, oxygenation and biocompatibility and their use in modern cardiac surgery. The journal is at the forefront of international research and development and presents an appropriately multidisciplinary approach to perfusion science.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信