In vitro comparison of the color degradation of two computer-aided design/computer-aided manufacturing provisional materials: A 12-month simulation.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Suzanna Maria Sayegh, Maha Daou, Georges Najjar, Elie Zebouni
{"title":"<i>In vitro</i> comparison of the color degradation of two computer-aided design/computer-aided manufacturing provisional materials: A 12-month simulation.","authors":"Suzanna Maria Sayegh, Maha Daou, Georges Najjar, Elie Zebouni","doi":"10.4103/jips.jips_119_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study evaluated the color aging of two computer aided design/computer aided manufacturing (CAD/CAM) provisional materials of different compositions (polymethyl methacrylate and composite resin) after exposure to thermal aging and immersion in coffee for 3, 6, and 12 intraoral months.</p><p><strong>Setting and design: </strong>The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon.</p><p><strong>Materials and methods: </strong>The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp<sup>®</sup> and Ceramill<sup>®</sup> TEMP were measured using the VITA Linearguide 3D MASTER<sup>®</sup> and a conversion table to extract the CIE LFNx01aFNx01bFNx01 values on a white background (n = 30).</p><p><strong>Statistical analysis used: </strong>The color differences ΔE at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests.</p><p><strong>Results: </strong>The mean ΔE<sub>T1/T0</sub>, ΔE<sub>T2/T0</sub>, and ΔE<sub>T3/T0</sub> values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp<sup>®</sup> and the Ceramill<sup>®</sup> TEMP groups. In addition, the increase in ΔE overtime was significantly greater in the Ceramill<sup>®</sup> TEMP group compared to the VITA CAD Temp<sup>®</sup> group.</p><p><strong>Conclusions: </strong>The Ceramill<sup>®</sup> TEMP changed color more and faster than the VITA CAD Temp<sup>®</sup>. In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"23 1","pages":"38-44"},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10088442/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_119_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study evaluated the color aging of two computer aided design/computer aided manufacturing (CAD/CAM) provisional materials of different compositions (polymethyl methacrylate and composite resin) after exposure to thermal aging and immersion in coffee for 3, 6, and 12 intraoral months.

Setting and design: The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon.

Materials and methods: The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp® and Ceramill® TEMP were measured using the VITA Linearguide 3D MASTER® and a conversion table to extract the CIE LFNx01aFNx01bFNx01 values on a white background (n = 30).

Statistical analysis used: The color differences ΔE at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests.

Results: The mean ΔET1/T0, ΔET2/T0, and ΔET3/T0 values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp® and the Ceramill® TEMP groups. In addition, the increase in ΔE overtime was significantly greater in the Ceramill® TEMP group compared to the VITA CAD Temp® group.

Conclusions: The Ceramill® TEMP changed color more and faster than the VITA CAD Temp®. In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade.

两种计算机辅助设计/计算机辅助制造临时材料颜色降解的体外比较:12个月的模拟。
目的:本研究评估了两种不同成分的计算机辅助设计/计算机辅助制造(CAD/CAM)临时材料(聚甲基丙烯酸甲酯和复合树脂)在暴露于热老化和浸泡在咖啡中3、6和12个月后的口内颜色老化。设置和设计:目前的体外研究于2021年9月至12月在黎巴嫩贝鲁特圣约瑟夫大学的颅面实验室进行。材料和方法:使用VITA Linearguide 3D MASTER®和转换表测量VITA CAD Temp®和Ceramill®Temp的2.0 mm厚、10.0 mm直径圆盘状试样的阴影,以提取白色背景上的CIE LFNx01aFNx01bFNx01值(n=30)。使用的统计分析:通过重复测量方差分析、Bonferroni多重比较、单变量分析和单样本t检验计算和分析3个月、6个月和12个月时的色差ΔE。结果:VITA CAD Temp®和Ceramill®Temp组的平均ΔET1/T0、ΔET2/T0和ΔET3/T0值显著高于可接受性和可感知性的临界值。此外,与VITA CAD TEMP®组相比,Ceramill®TEMP组的ΔE超时增加幅度明显更大。结论:Ceramill®TEMP比VITA CAD TEMP®变色更快。此外,无论是在3个月、6个月还是12个月时,与最初的色调相比,这两种材料的颜色变化不仅是可察觉的,而且是不可接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信