Periodontal Pocket Therapy Using a Class IV Dental Diode Laser in Dogs: A Retrospective Analysis.

IF 0.7 4区 农林科学 Q3 VETERINARY SCIENCES
Journal of Veterinary Dentistry Pub Date : 2024-03-01 Epub Date: 2023-03-22 DOI:10.1177/08987564231164493
Ilana Zuckerman, Judy Force, Alexandra L Hanlon, Alicia J Lozano, Wenyan Ji, Jamie G Anderson
{"title":"Periodontal Pocket Therapy Using a Class IV Dental Diode Laser in Dogs: A Retrospective Analysis.","authors":"Ilana Zuckerman, Judy Force, Alexandra L Hanlon, Alicia J Lozano, Wenyan Ji, Jamie G Anderson","doi":"10.1177/08987564231164493","DOIUrl":null,"url":null,"abstract":"<p><p>Class IV dental diode lasers have been introduced as a nonsurgical therapy for periodontal pockets in veterinary and human dentistry. This retrospective case series evaluates the use of Class IV dental diode laser therapy for abnormal periodontal pockets in a specialty veterinary dental practice. A hypothesis that the Class IV diode dental laser is a useful adjuvant modality in canine periodontal pocket therapy in the reduction of clinical pocket depth was made. This article discusses and demonstrates diode laser use in periodontal pocket therapy in a specialty veterinary dental practice and reviews the current literature. Inclusion in this study was limited to client-owned dogs with noted periodontal pocketing on any tooth type between 3 and 6 mm, which were treated with closed root planing (RP/C) and laser therapy who returned in 6 to 7 months for recheck of the pockets from the years 2017 to 2020. Twelve patients met the inclusion criteria. A total of 128 periodontal pockets were included in the study. Each periodontal pocket was a case receiving therapy. The mean periodontal pocket depth before the treatment is measured as 3.35 mm. The mean pocket depth of the periodontal pockets following treatment was 0.59 mm. The mean improvement in periodontal pocket depths after diode laser therapy when considering patient and tooth number using linear mixed-effects modeling was 2.63 mm (95% confidence interval [CI]: 1.81-3.46, <i>P </i>< .0001). No statistically significant results were observed for pocket type, as <i>P</i> values were greater than .05.</p>","PeriodicalId":17584,"journal":{"name":"Journal of Veterinary Dentistry","volume":" ","pages":"155-162"},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Dentistry","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/08987564231164493","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Class IV dental diode lasers have been introduced as a nonsurgical therapy for periodontal pockets in veterinary and human dentistry. This retrospective case series evaluates the use of Class IV dental diode laser therapy for abnormal periodontal pockets in a specialty veterinary dental practice. A hypothesis that the Class IV diode dental laser is a useful adjuvant modality in canine periodontal pocket therapy in the reduction of clinical pocket depth was made. This article discusses and demonstrates diode laser use in periodontal pocket therapy in a specialty veterinary dental practice and reviews the current literature. Inclusion in this study was limited to client-owned dogs with noted periodontal pocketing on any tooth type between 3 and 6 mm, which were treated with closed root planing (RP/C) and laser therapy who returned in 6 to 7 months for recheck of the pockets from the years 2017 to 2020. Twelve patients met the inclusion criteria. A total of 128 periodontal pockets were included in the study. Each periodontal pocket was a case receiving therapy. The mean periodontal pocket depth before the treatment is measured as 3.35 mm. The mean pocket depth of the periodontal pockets following treatment was 0.59 mm. The mean improvement in periodontal pocket depths after diode laser therapy when considering patient and tooth number using linear mixed-effects modeling was 2.63 mm (95% confidence interval [CI]: 1.81-3.46, P < .0001). No statistically significant results were observed for pocket type, as P values were greater than .05.

在狗身上使用 IV 级牙科二极管激光器进行牙周袋治疗:回顾性分析。
在兽医和人类牙科领域,第四类牙科二极管激光已被引入作为治疗牙周袋的非手术疗法。本回顾性系列病例评估了在一家专业兽医牙科诊所使用 IV 类牙科二极管激光治疗异常牙周袋的情况。我们提出了一个假设,即 IV 级二极管牙科激光是犬牙周袋治疗中一种有效的辅助方式,可减轻临床牙周袋深度。本文讨论并展示了二极管激光在专业兽医牙科诊所牙周袋治疗中的应用,并回顾了当前的文献。本研究的研究对象仅限于客户饲养的犬只,这些犬只的任何牙齿类型都存在3至6毫米的牙周袋,这些犬只接受了封闭式根面平整术(RP/C)和激光治疗,并在6至7个月后返回进行复查,复查时间为2017年至2020年。12名患者符合纳入标准。研究共纳入了 128 个牙周袋。每个牙周袋都是一个接受治疗的病例。治疗前的平均牙周袋深度为 3.35 毫米。治疗后牙周袋的平均深度为 0.59 毫米。使用线性混合效应模型计算患者和牙齿数量时,二极管激光治疗后牙周袋深度的平均改善幅度为 2.63 毫米(95% 置信区间 [CI]:1.81-3.46,P<0.05):P值大于0.05。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Veterinary Dentistry
Journal of Veterinary Dentistry VETERINARY SCIENCES-
CiteScore
1.00
自引率
10.00%
发文量
59
期刊介绍: The Journal of Veterinary Dentistry (JOVD) is the official peer-reviewed publication of the Foundation for Veterinary Dentistry. The JOVD provides a continuing education forum for veterinary dental scientists, veterinarians, dentists, and veterinary/dental technicians and hygienists who are engaged in veterinary dental practice. JOVD articles provide practical and scientifically sound information covering not only the medical and surgical aspects, but also specific categories as they relate to clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信