Ali A Almomani, Ala'a S Shraim, Ali M Atoom, Majeed Bayan A Abdel, Jehad F Alhmoud
{"title":"Evaluation of the validity of the pre-marriage mean corpuscular volume value as a predictive test for b-thalassemia carrier status.","authors":"Ali A Almomani, Ala'a S Shraim, Ali M Atoom, Majeed Bayan A Abdel, Jehad F Alhmoud","doi":"10.5937/jomb0-37682","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The national mandatory premarital screening test is based on mean corpuscular volume (MCV) > 80 fL value for the detection of β-thalassemia to provide acceptance for marriage. The objective of this study is to assess the efficacy of MCV as a screening test for β-thalassemia trait in the present population.</p><p><strong>Methods: </strong>This study was conducted on 418 blood samples collected from adult individuals. The diagnosis of β-thalassemia carrier was given to those having HbA<sub>2</sub> values equal to or above 3.5%. The diagnostic reliability of different RBC indices and formulas in discriminating cases of β-thalassemia trait were evaluated. Finally, a new index called \"Momani\" was determined based on MCV, RDW and RBC count.</p><p><strong>Results: </strong>β-thalassemia trait was identified in 10% of the cases. The measured MCV value was significantly lower in β-thalassemia carrier group compared to non-carrier group (p = <0.001). MCV value and RBC count showed a higher diagnostic reliability than other RBC indices. We found that MCV ≤ 74.45 fL is more suitable cutoff value of MCV with 86.2% specificity, 71.4% sensitivity, 36.6% positive predictive value, and 96.4% negative predictive value. Finally, our index \"Momani\" was found to be useful in predicting carrier and paralleled the performance of Sirdah, Mentzer, and Ehsani indices.</p><p><strong>Conclusions: </strong>MCV<80 is a useful but not a perfect cutoff point for the screening of β-thalassemia carriers from noncarriers. The diagnostic accuracy of MCV can be improved by selecting a new cutoff value. Moreover, \"Momani\" index shows good discrimination ability in diagnosing β-thalassemia carrier in our population.</p>","PeriodicalId":16175,"journal":{"name":"Journal of Medical Biochemistry","volume":"42 2","pages":"195-205"},"PeriodicalIF":2.0000,"publicationDate":"2023-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10040200/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5937/jomb0-37682","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The national mandatory premarital screening test is based on mean corpuscular volume (MCV) > 80 fL value for the detection of β-thalassemia to provide acceptance for marriage. The objective of this study is to assess the efficacy of MCV as a screening test for β-thalassemia trait in the present population.
Methods: This study was conducted on 418 blood samples collected from adult individuals. The diagnosis of β-thalassemia carrier was given to those having HbA2 values equal to or above 3.5%. The diagnostic reliability of different RBC indices and formulas in discriminating cases of β-thalassemia trait were evaluated. Finally, a new index called "Momani" was determined based on MCV, RDW and RBC count.
Results: β-thalassemia trait was identified in 10% of the cases. The measured MCV value was significantly lower in β-thalassemia carrier group compared to non-carrier group (p = <0.001). MCV value and RBC count showed a higher diagnostic reliability than other RBC indices. We found that MCV ≤ 74.45 fL is more suitable cutoff value of MCV with 86.2% specificity, 71.4% sensitivity, 36.6% positive predictive value, and 96.4% negative predictive value. Finally, our index "Momani" was found to be useful in predicting carrier and paralleled the performance of Sirdah, Mentzer, and Ehsani indices.
Conclusions: MCV<80 is a useful but not a perfect cutoff point for the screening of β-thalassemia carriers from noncarriers. The diagnostic accuracy of MCV can be improved by selecting a new cutoff value. Moreover, "Momani" index shows good discrimination ability in diagnosing β-thalassemia carrier in our population.
期刊介绍:
The JOURNAL OF MEDICAL BIOCHEMISTRY (J MED BIOCHEM) is the official journal of the Society of Medical Biochemists of Serbia with international peer-review. Papers are independently reviewed by at least two reviewers selected by the Editors as Blind Peer Reviews. The Journal of Medical Biochemistry is published quarterly.
The Journal publishes original scientific and specialized articles on all aspects of
clinical and medical biochemistry,
molecular medicine,
clinical hematology and coagulation,
clinical immunology and autoimmunity,
clinical microbiology,
virology,
clinical genomics and molecular biology,
genetic epidemiology,
drug measurement,
evaluation of diagnostic markers,
new reagents and laboratory equipment,
reference materials and methods,
reference values,
laboratory organization,
automation,
quality control,
clinical metrology,
all related scientific disciplines where chemistry, biochemistry, molecular biology and immunochemistry deal with the study of normal and pathologic processes in human beings.