Formal specification and verification of fault location, isolation and service restoration of local topology model based on distributed processing for active distribution network

IF 1.7 Q3 COMPUTER SCIENCE, INFORMATION SYSTEMS
Jiaming Weng, Dong Liu, Yingxu Liu
{"title":"Formal specification and verification of fault location, isolation and service restoration of local topology model based on distributed processing for active distribution network","authors":"Jiaming Weng,&nbsp;Dong Liu,&nbsp;Yingxu Liu","doi":"10.1049/cps2.12005","DOIUrl":null,"url":null,"abstract":"<p>Active distribution network (ADN) technology, as an important trend of the future smart distribution grid, is able to effectively absorb distributed energy resource (DER), to reasonably optimise grid-load operation characteristics, and to safely support the reliability of power supply. Through enhancing energy utilisation efficiency and friendly interaction with user access, ADN technology is also able to comprehensively improve the power supply reliability of the distribution network. However, distributed feeder automation (FA), as an important part of ADN technology, will also meet new problems and challenges with the access of DER in the distribution network. The formal method can analyse the correctness and effectiveness of a distributed fault processing algorithm from mathematical logic, which provides an important theoretical basis for distributed fault processing. The focus herein is on the formal description and verification of topology modelling in fault location, isolation, and service restoration (FLISR) based on distributed processing. By abstracting and simplifying the complex power system features, the adaptability of the formal method is solved. The logical correctness of the topology model in FLISR based on distributed processing is verified. Finally, the distributed local topology model and algorithm is verified through a formal method using an actual ADN example.</p>","PeriodicalId":36881,"journal":{"name":"IET Cyber-Physical Systems: Theory and Applications","volume":"6 3","pages":"116-124"},"PeriodicalIF":1.7000,"publicationDate":"2021-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/cps2.12005","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Cyber-Physical Systems: Theory and Applications","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/cps2.12005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INFORMATION SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Active distribution network (ADN) technology, as an important trend of the future smart distribution grid, is able to effectively absorb distributed energy resource (DER), to reasonably optimise grid-load operation characteristics, and to safely support the reliability of power supply. Through enhancing energy utilisation efficiency and friendly interaction with user access, ADN technology is also able to comprehensively improve the power supply reliability of the distribution network. However, distributed feeder automation (FA), as an important part of ADN technology, will also meet new problems and challenges with the access of DER in the distribution network. The formal method can analyse the correctness and effectiveness of a distributed fault processing algorithm from mathematical logic, which provides an important theoretical basis for distributed fault processing. The focus herein is on the formal description and verification of topology modelling in fault location, isolation, and service restoration (FLISR) based on distributed processing. By abstracting and simplifying the complex power system features, the adaptability of the formal method is solved. The logical correctness of the topology model in FLISR based on distributed processing is verified. Finally, the distributed local topology model and algorithm is verified through a formal method using an actual ADN example.

Abstract Image

基于分布式处理的有源配电网局部拓扑模型故障定位、隔离和业务恢复的形式化规范与验证
主动配电网(ADN)技术能够有效吸收分布式能源,合理优化电网负荷运行特性,安全保障供电可靠性,是未来智能配电网发展的重要趋势。通过提高能源利用效率和与用户接入的友好交互,ADN技术还能够全面提高配电网的供电可靠性。然而,分布式馈线自动化作为ADN技术的重要组成部分,随着DER在配电网中的接入,也将面临新的问题和挑战。形式化方法可以从数学逻辑上分析分布式故障处理算法的正确性和有效性,为分布式故障处理提供了重要的理论依据。本文重点研究了基于分布式处理的故障定位、隔离和服务恢复(FLISR)中拓扑建模的形式化描述和验证。通过对复杂电力系统特征的抽象和简化,解决了形式化方法的适应性问题。验证了基于分布式处理的FLISR拓扑模型的逻辑正确性。最后,通过一个实际ADN实例,通过形式化方法对分布式局部拓扑模型和算法进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IET Cyber-Physical Systems: Theory and Applications
IET Cyber-Physical Systems: Theory and Applications Computer Science-Computer Networks and Communications
CiteScore
5.40
自引率
6.70%
发文量
17
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信