The flexural testing of some prestressed HAC Beams

B. Mayfield , J. Morris , M.J. Wyatt
{"title":"The flexural testing of some prestressed HAC Beams","authors":"B. Mayfield ,&nbsp;J. Morris ,&nbsp;M.J. Wyatt","doi":"10.1016/0007-3628(75)90038-9","DOIUrl":null,"url":null,"abstract":"<div><p>Flexural tests on X7/5 wire prestressed concrete beams made with High Alumina Cement (HAC) are described. The beams were artificially converted (in the range 10–100±5%) and observations were made on central deflection, strains, ultrasonic pulse velocities, cube compressive and prism flexural strengths, and concrete moduli.</p><p>Although the conversion caused some major changes in the concrete properties the effect on the ultimate moment capacity of the beams was minor, due to the under-reinforced nature of this particular section at these particular concrete strengths.</p></div>","PeriodicalId":9442,"journal":{"name":"Building Science","volume":"10 4","pages":"Pages 263-270"},"PeriodicalIF":0.0000,"publicationDate":"1975-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0007-3628(75)90038-9","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Science","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0007362875900389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Flexural tests on X7/5 wire prestressed concrete beams made with High Alumina Cement (HAC) are described. The beams were artificially converted (in the range 10–100±5%) and observations were made on central deflection, strains, ultrasonic pulse velocities, cube compressive and prism flexural strengths, and concrete moduli.

Although the conversion caused some major changes in the concrete properties the effect on the ultimate moment capacity of the beams was minor, due to the under-reinforced nature of this particular section at these particular concrete strengths.

几种预应力混凝土梁的抗弯试验
介绍了高铝水泥(HAC) X7/5钢丝预应力混凝土梁的受弯试验。在10-100±5%的范围内对梁进行人工转换,并对中心挠度、应变、超声脉冲速度、立方体抗压强度和棱镜抗折强度以及混凝土模量进行观测。虽然转换引起了混凝土性能的一些重大变化,但由于这一特定部分在这些特定混凝土强度下的加固性质,对梁的极限弯矩能力的影响很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信