Moe Kojima, Naoya Tanabe, Yu Kojima, Koichi Tamura, Hiroo Takahashi, Jun Ito
{"title":"Usefulness of a Novel Vascular Access Management Method Using a Laser Blood Flowmeter.","authors":"Moe Kojima, Naoya Tanabe, Yu Kojima, Koichi Tamura, Hiroo Takahashi, Jun Ito","doi":"10.1159/000528897","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Various methods for vascular access (VA) management have been studied. We investigated the usefulness of a new, simple, and quantitative VA management method using the Pocket LDF® laser blood flowmeter (hereinafter \"LDF\") that noninvasively measures peripheral circulation flow.</p><p><strong>Methods: </strong>Peripheral circulation flow was measured in 82 patients (43 men) on maintenance hemodialysis with an arteriovenous fistula (AVF). The shunt symmetry index (SSI) was calculated as peripheral circulation flow in the AVF limb divided by that in the non-AVF limb. SSI was used for microcirculation evaluation and also compared by AVF site. Patients undergoing vascular access interventional therapy (VAIVT) underwent ultrasound evaluation (Doppler ultrasonography) of the AVF and SSI measurement before and after VAIVT. SSI was compared between those who did and did not require VAIVT, and the cutoff value for SSI was determined by receiver operating characteristic curve (ROC) analysis.</p><p><strong>Results: </strong>As many as 86% of the patients who were measured peripheral circulation flow had SSI <1.0, which indicates that AVF reduced peripheral circulation flow. All patients who underwent VAIVT showed a decrease in SSI to <1.0 after VAIVT, probably due to improvement of stenosis. SSI differed significantly between patients who did and did not require VAIVT (1.20 ± 0.49 vs. 0.65 ± 0.33, p < 0.001), which indicates that SSI is affected by the presence of stenosis in the proximal vein of the VA anastomosis. In patients with SSI ≥1.0, stenosis of the proximal vein of the AVF caused stasis of blood flow, resulting in increased peripheral blood flow. AVF site seems to have no impact on peripheral circulation flow. The SSI cutoff value for the screening of proximal vein stenosis was 1.06 (sensitivity: 0.69, specificity: 0.93, area under the curve: 0.81).</p><p><strong>Conclusion: </strong>Based on the ROC analysis, we recommend considering AVF ultrasound for SSI >1.06. Our results suggest the usefulness of the described VA management method using the LDF.</p>","PeriodicalId":9584,"journal":{"name":"Cardiorenal Medicine","volume":" ","pages":"232-237"},"PeriodicalIF":2.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10664318/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiorenal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000528897","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Various methods for vascular access (VA) management have been studied. We investigated the usefulness of a new, simple, and quantitative VA management method using the Pocket LDF® laser blood flowmeter (hereinafter "LDF") that noninvasively measures peripheral circulation flow.
Methods: Peripheral circulation flow was measured in 82 patients (43 men) on maintenance hemodialysis with an arteriovenous fistula (AVF). The shunt symmetry index (SSI) was calculated as peripheral circulation flow in the AVF limb divided by that in the non-AVF limb. SSI was used for microcirculation evaluation and also compared by AVF site. Patients undergoing vascular access interventional therapy (VAIVT) underwent ultrasound evaluation (Doppler ultrasonography) of the AVF and SSI measurement before and after VAIVT. SSI was compared between those who did and did not require VAIVT, and the cutoff value for SSI was determined by receiver operating characteristic curve (ROC) analysis.
Results: As many as 86% of the patients who were measured peripheral circulation flow had SSI <1.0, which indicates that AVF reduced peripheral circulation flow. All patients who underwent VAIVT showed a decrease in SSI to <1.0 after VAIVT, probably due to improvement of stenosis. SSI differed significantly between patients who did and did not require VAIVT (1.20 ± 0.49 vs. 0.65 ± 0.33, p < 0.001), which indicates that SSI is affected by the presence of stenosis in the proximal vein of the VA anastomosis. In patients with SSI ≥1.0, stenosis of the proximal vein of the AVF caused stasis of blood flow, resulting in increased peripheral blood flow. AVF site seems to have no impact on peripheral circulation flow. The SSI cutoff value for the screening of proximal vein stenosis was 1.06 (sensitivity: 0.69, specificity: 0.93, area under the curve: 0.81).
Conclusion: Based on the ROC analysis, we recommend considering AVF ultrasound for SSI >1.06. Our results suggest the usefulness of the described VA management method using the LDF.
期刊介绍:
The journal ''Cardiorenal Medicine'' explores the mechanisms by which obesity and other metabolic abnormalities promote the pathogenesis and progression of heart and kidney disease (cardiorenal metabolic syndrome). It provides an interdisciplinary platform for the advancement of research and clinical practice, focussing on translational issues.