{"title":"Novel Self-Expanding Interwoven Nitinol Stent for Treating Femoropopliteal Artery Disease: 12-Month Results of Single-Center First-in-Man Study.","authors":"Shuofei Yang, Qihong Ni, Weilun Wang, Jiaquan Chen, Xiangjiang Guo, Meng Ye, Lan Zhang, Guanhua Xue","doi":"10.1177/15266028231159243","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the safety and efficacy of Innospring<sup>®</sup> stent, a novel self-expanding interwoven nitinol stent, in treating femoropopliteal atherosclerotic lesions.</p><p><strong>Methods: </strong>A prospective, single-center, single-arm, first-in-human study enrolled 15 patients (mean age 73.1 years; 13 men) to evaluate the safety and efficacy of the Innospring<sup>®</sup> stent monitored by core laboratories. The inclusion criteria were claudication or ischemic rest pain, de novo lesions or nonstented restenosis, >70% stenosis, lesion length <20 cm, and a reference vessel diameter of 4-7 mm. The primary safety endpoint was 30-day major adverse events. The primary efficacy end point was stent patency at 12 months. Follow-up evaluations were conducted at 30 days, 6 months, and 12 months.</p><p><strong>Results: </strong>The lesion length was 6.1 ± 3.5 mm. Fourteen (93.3%) patients had lesions of the superficial femoral artery and 3 (20.0%) patients had lesions of the popliteal artery. Nine (60.0%) patients had moderate-to-severe calcified lesion. Technical and procedural success was 100%. No patients experienced major adverse events in the first 30 days. The Rutherford category showed significant and sustained improvement at 6 and 12 months. The 12-month follow-up radiographs obtained in 13 patients confirmed the absence of stent fractures in 100% of examinations. The cumulative primary stent patency rate at 6 and 12 months were 93.3% and 84.6%, respectively.</p><p><strong>Conclusion: </strong>Stenting of the superficial femoral and popliteal arteries using the Innospring<sup>®</sup> stent is safe and effective. This competing interwoven nitinol stent may provide superior stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.</p><p><strong>Clinical impact: </strong>Endovascular recanalization is a widely accepted and recommended treatment for symptomatic peripheral artery diseases. The Innospring® stent is a novel self-expanding interwoven stent containing eight nitinol wires with additional radial force, fracture-resistance, and visibility under fluoroscopy. This first-in-human study using the Innospring® stent in patients with femoropopliteal occlusive disease reported that stenting of the superficial femoral and popliteal arteries using the Innospring® stent is safe and effective. This competing interwoven nitinol stent may provide an impressive stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231159243","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/16 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the safety and efficacy of Innospring® stent, a novel self-expanding interwoven nitinol stent, in treating femoropopliteal atherosclerotic lesions.
Methods: A prospective, single-center, single-arm, first-in-human study enrolled 15 patients (mean age 73.1 years; 13 men) to evaluate the safety and efficacy of the Innospring® stent monitored by core laboratories. The inclusion criteria were claudication or ischemic rest pain, de novo lesions or nonstented restenosis, >70% stenosis, lesion length <20 cm, and a reference vessel diameter of 4-7 mm. The primary safety endpoint was 30-day major adverse events. The primary efficacy end point was stent patency at 12 months. Follow-up evaluations were conducted at 30 days, 6 months, and 12 months.
Results: The lesion length was 6.1 ± 3.5 mm. Fourteen (93.3%) patients had lesions of the superficial femoral artery and 3 (20.0%) patients had lesions of the popliteal artery. Nine (60.0%) patients had moderate-to-severe calcified lesion. Technical and procedural success was 100%. No patients experienced major adverse events in the first 30 days. The Rutherford category showed significant and sustained improvement at 6 and 12 months. The 12-month follow-up radiographs obtained in 13 patients confirmed the absence of stent fractures in 100% of examinations. The cumulative primary stent patency rate at 6 and 12 months were 93.3% and 84.6%, respectively.
Conclusion: Stenting of the superficial femoral and popliteal arteries using the Innospring® stent is safe and effective. This competing interwoven nitinol stent may provide superior stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.
Clinical impact: Endovascular recanalization is a widely accepted and recommended treatment for symptomatic peripheral artery diseases. The Innospring® stent is a novel self-expanding interwoven stent containing eight nitinol wires with additional radial force, fracture-resistance, and visibility under fluoroscopy. This first-in-human study using the Innospring® stent in patients with femoropopliteal occlusive disease reported that stenting of the superficial femoral and popliteal arteries using the Innospring® stent is safe and effective. This competing interwoven nitinol stent may provide an impressive stent integrity and fracture-resistance as well as serve areas under extreme mechanical stress.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.