A 2-day cardiopulmonary exercise test in chronic fatigue syndrome patients who were exposed to humidifier disinfectants.

Environmental analysis, health and toxicology Pub Date : 2022-12-01 Epub Date: 2022-11-03 DOI:10.5620/eaht.2022033
Jong-Han Leem, Hyoung-Eun Jeon, Hun Nam, Hwan-Cheol Kim, Kyung-Lim Joa
{"title":"A 2-day cardiopulmonary exercise test in chronic fatigue syndrome patients who were exposed to humidifier disinfectants.","authors":"Jong-Han Leem, Hyoung-Eun Jeon, Hun Nam, Hwan-Cheol Kim, Kyung-Lim Joa","doi":"10.5620/eaht.2022033","DOIUrl":null,"url":null,"abstract":"<p><p>Some survivors of humidifier disinfectants (HDs) complain of chronic, inexplicable fatigue, and post-exertional malaise (PEM). Two-day cardiopulmonary exercise tests (CPETs) performed 24 hours apart (2-day CPET protocol) are increasingly employed to evaluate PEM and related disabilities among individuals with chronic fatigue syndrome (CFS). The purpose of this study was to assess the reproducibility of CPET variables in individuals who had been exposed to HD and to show that 2-day CPET is an objective means of differentiating between fatigue conditions in people with CFS symptoms who have been exposed to HDs. Twenty-nine HD survivors with CFS symptoms were enrolled in this study. To document and assess PEM in CFS, a 2-day CPET was conducted to measure baseline functional capacity (CPET1) and provoke PEM. Twenty-four hours later, a second CPET assessed changes in related variables, focusing on PEM effects on functional capacity. This CPET also measured changes in energy production and physiological function, objectively documenting PEM effects. In the 2-day CPET, the peak oxygen consumption (VO2peak), VO2 at ventilatory threshold (VO2@VT), time to reach VO2peak, and time to reach VO2@VT were significantly decreased (p<0.001). The peak O2 pulse and O2 pulse at VT also decreased significantly (p<0.001). A 6-minute walk test revealed significantly decreased distance (p<0.01). This is the first study to conduct a 2-day consecutive CPET in previously exposed HD participants with CFS symptoms. Our results confirm previous work that demonstrated abnormal responses to PEM in CFS patients. Therefore, a 2-day CPET is an objective measure to differentiate fatigue conditions in people with CFS symptoms who have been exposed to HDs.</p>","PeriodicalId":11867,"journal":{"name":"Environmental analysis, health and toxicology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/62/3f/eaht-37-4-e2022033.PMC10014750.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental analysis, health and toxicology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5620/eaht.2022033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/11/3 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Some survivors of humidifier disinfectants (HDs) complain of chronic, inexplicable fatigue, and post-exertional malaise (PEM). Two-day cardiopulmonary exercise tests (CPETs) performed 24 hours apart (2-day CPET protocol) are increasingly employed to evaluate PEM and related disabilities among individuals with chronic fatigue syndrome (CFS). The purpose of this study was to assess the reproducibility of CPET variables in individuals who had been exposed to HD and to show that 2-day CPET is an objective means of differentiating between fatigue conditions in people with CFS symptoms who have been exposed to HDs. Twenty-nine HD survivors with CFS symptoms were enrolled in this study. To document and assess PEM in CFS, a 2-day CPET was conducted to measure baseline functional capacity (CPET1) and provoke PEM. Twenty-four hours later, a second CPET assessed changes in related variables, focusing on PEM effects on functional capacity. This CPET also measured changes in energy production and physiological function, objectively documenting PEM effects. In the 2-day CPET, the peak oxygen consumption (VO2peak), VO2 at ventilatory threshold (VO2@VT), time to reach VO2peak, and time to reach VO2@VT were significantly decreased (p<0.001). The peak O2 pulse and O2 pulse at VT also decreased significantly (p<0.001). A 6-minute walk test revealed significantly decreased distance (p<0.01). This is the first study to conduct a 2-day consecutive CPET in previously exposed HD participants with CFS symptoms. Our results confirm previous work that demonstrated abnormal responses to PEM in CFS patients. Therefore, a 2-day CPET is an objective measure to differentiate fatigue conditions in people with CFS symptoms who have been exposed to HDs.

对接触过加湿器消毒剂的慢性疲劳综合征患者进行为期 2 天的心肺运动测试。
一些使用过加湿器消毒剂(HDs)的幸存者抱怨自己长期感到莫名其妙的疲劳和运动后乏力(PEM)。越来越多的慢性疲劳综合征(CFS)患者开始采用间隔 24 小时进行两天心肺运动测试(CPET)(两天 CPET 方案)来评估 PEM 和相关残疾。本研究的目的是评估 CPET 变量在接触过 HD 的患者中的可重复性,并证明 2 天 CPET 是区分接触过 HD 的 CFS 症状患者疲劳状况的客观方法。本研究招募了 29 名有 CFS 症状的 HD 幸存者。为了记录和评估 CFS 中的 PEM,进行了为期两天的 CPET,以测量基线功能能力(CPET1)并引发 PEM。24 小时后,进行第二次 CPET,评估相关变量的变化,重点关注 PEM 对功能能力的影响。该 CPET 还测量了能量产生和生理功能的变化,客观记录了 PEM 的影响。在为期两天的 CPET 中,峰值耗氧量(VO2peak)、通气阈值的 VO2(VO2@VT)、达到峰值 VO2 的时间和达到 VO2@VT 的时间均显著下降(p<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信