Feline hip joint anatomy in magnetic resonance images

Anatomia Pub Date : 2019-07-26 DOI:10.1111/ahe.12466
J. Głodek, Kamila Milewska, Angelika Tobolska, Ł. Grabarczyk, W. Maksymowicz, I. Bada, Z. Adamiak
{"title":"Feline hip joint anatomy in magnetic resonance images","authors":"J. Głodek, Kamila Milewska, Angelika Tobolska, Ł. Grabarczyk, W. Maksymowicz, I. Bada, Z. Adamiak","doi":"10.1111/ahe.12466","DOIUrl":null,"url":null,"abstract":"The aim of this study was to develop an anatomical model of the feline hip joint for low‐field magnetic resonance imaging (LF‐MRI) based on high‐field magnetic resonance imaging (HF‐MRI). The study was performed on six adult clinically healthy European shorthair cats, aged 1–3 years, with body weight of 2.8–4.4 kg. The animals were examined with the use of the Vet‐MRI Grande Esaote LF (0.25 T) scanner and high‐field Siemens Magnetom TRIO (3 T) MRI scanner. In the LF‐MRI, most satisfactory results in T1‐weighted images were obtained when TE was 26 ms in all three planes and when TR was 350–950 ms in the transverse plane, 950–1150 ms in the sagittal plane and 520–750 ms in the dorsal plane. In T2‐weighted images, TE was 90 ms in the transverse and dorsal plane and 120 ms in the sagittal plane. The results were presented as images acquired with LF‐MRI scanners in three planes. The slice thickness was 3 mm for each plane. In LF‐MRI, muscles in the hip joint region and round ligament were well visualized. Unlike in LF‐MRI, the cross section of the femoral nerve was identified in HF‐MRI scans. In examinations of the feline hip joint, the main limitations of LF‐MRI were a lack of reliable contrast between articular cartilage and synovial fluid as well as longer scan time. Despite the above, LF‐MRI images were characterized by good contrast between bones and the surrounding soft tissues.","PeriodicalId":7888,"journal":{"name":"Anatomia","volume":"20 1","pages":"449 - 454"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/ahe.12466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to develop an anatomical model of the feline hip joint for low‐field magnetic resonance imaging (LF‐MRI) based on high‐field magnetic resonance imaging (HF‐MRI). The study was performed on six adult clinically healthy European shorthair cats, aged 1–3 years, with body weight of 2.8–4.4 kg. The animals were examined with the use of the Vet‐MRI Grande Esaote LF (0.25 T) scanner and high‐field Siemens Magnetom TRIO (3 T) MRI scanner. In the LF‐MRI, most satisfactory results in T1‐weighted images were obtained when TE was 26 ms in all three planes and when TR was 350–950 ms in the transverse plane, 950–1150 ms in the sagittal plane and 520–750 ms in the dorsal plane. In T2‐weighted images, TE was 90 ms in the transverse and dorsal plane and 120 ms in the sagittal plane. The results were presented as images acquired with LF‐MRI scanners in three planes. The slice thickness was 3 mm for each plane. In LF‐MRI, muscles in the hip joint region and round ligament were well visualized. Unlike in LF‐MRI, the cross section of the femoral nerve was identified in HF‐MRI scans. In examinations of the feline hip joint, the main limitations of LF‐MRI were a lack of reliable contrast between articular cartilage and synovial fluid as well as longer scan time. Despite the above, LF‐MRI images were characterized by good contrast between bones and the surrounding soft tissues.
猫髋关节的磁共振图像解剖
本研究的目的是在高场磁共振成像(HF - MRI)的基础上建立一种用于低场磁共振成像(LF - MRI)的猫髋关节解剖模型。研究对象为6只临床健康的成年欧洲短毛猫,年龄1-3岁,体重2.8-4.4 kg。使用Vet - MRI Grande Esaote LF (0.25 T)扫描仪和高场Siemens Magnetom TRIO (3 T) MRI扫描仪对动物进行检查。在LF - MRI中,当TE在三个平面均为26 ms, TR在横切面为350-950 ms,矢状面为950-1150 ms,背侧面为520-750 ms时,T1 -加权图像获得最满意的结果。在T2加权图像中,TE在横背面为90 ms,在矢状面为120 ms。结果显示为LF‐MRI扫描仪在三个平面上获得的图像。每个平面的切片厚度为3mm。在LF - MRI中,髋关节区域和圆形韧带的肌肉清晰可见。与LF - MRI不同,HF - MRI扫描可识别股神经的横截面。在检查猫髋关节时,LF - MRI的主要局限性是缺乏可靠的关节软骨和滑液对比以及较长的扫描时间。尽管如此,LF - MRI图像的特点是骨骼和周围软组织之间有良好的对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书