Muammer Karakayali, Inanç Artac, Timor Omar, İbrahim Rencuzogullari, Yavuz Karabag, Tufan Cinar, Mehmet Altunova, Serif Hamideyin
{"title":"The association between frontal QRS-T angle and reverse dipper status in newly diagnosed hypertensive patients.","authors":"Muammer Karakayali, Inanç Artac, Timor Omar, İbrahim Rencuzogullari, Yavuz Karabag, Tufan Cinar, Mehmet Altunova, Serif Hamideyin","doi":"10.1097/MBP.0000000000000637","DOIUrl":null,"url":null,"abstract":"<p><p>The frontal QRS-T angle (fQRS-T angle) in ECG is a new measure of myocardial repolarization, in which a higher fQRS-T angle is linked with worse cardiac outcomes. Reverse dipper hypertension is also linked to poor cardiac outcomes. The purpose of this study was to investigate the association between the fQRS-T angle and reverse dipper status in individuals newly diagnosed with hypertension who did not have left ventricular hypertrophy (LVH). The investigation recruited 171 hypertensive individuals without LVH who underwent 24-h ambulatory blood pressure monitoring (ABPM). On the basis of the findings of 24-h ABPM, the study population was categorized into the following three groups: patients with dipper hypertension, non-dipper hypertension, and reverse dipper hypertension. LVH was defined by echocardiography. The fQRS-T angle was measured using the 12-lead ECG. The fQRS-T angle in individuals with reverse dipper hypertension was substantially greater than in patients with and without dipper hypertension (51° ± 28° vs. 28° ± 22° vs. 39° ± 25°, respectively, P < 0.001). The fQRS-T angle (odds ratio: 1.040, 95% confidence interval: 1.016-1.066; P = 0.001) was independently associated with reverse dipper hypertension according to multivariate analysis. In receiver operating characteristic curve analysis, the fQRS-T angle to predict reverse dipper hypertension was 33.5° with 76% sensitivity and 71% specificity. This study showed that an increased fQRS-T angle was associated with reverse dipper hypertension in newly diagnosed hypertensive patients without LVH.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000637","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 2
Abstract
The frontal QRS-T angle (fQRS-T angle) in ECG is a new measure of myocardial repolarization, in which a higher fQRS-T angle is linked with worse cardiac outcomes. Reverse dipper hypertension is also linked to poor cardiac outcomes. The purpose of this study was to investigate the association between the fQRS-T angle and reverse dipper status in individuals newly diagnosed with hypertension who did not have left ventricular hypertrophy (LVH). The investigation recruited 171 hypertensive individuals without LVH who underwent 24-h ambulatory blood pressure monitoring (ABPM). On the basis of the findings of 24-h ABPM, the study population was categorized into the following three groups: patients with dipper hypertension, non-dipper hypertension, and reverse dipper hypertension. LVH was defined by echocardiography. The fQRS-T angle was measured using the 12-lead ECG. The fQRS-T angle in individuals with reverse dipper hypertension was substantially greater than in patients with and without dipper hypertension (51° ± 28° vs. 28° ± 22° vs. 39° ± 25°, respectively, P < 0.001). The fQRS-T angle (odds ratio: 1.040, 95% confidence interval: 1.016-1.066; P = 0.001) was independently associated with reverse dipper hypertension according to multivariate analysis. In receiver operating characteristic curve analysis, the fQRS-T angle to predict reverse dipper hypertension was 33.5° with 76% sensitivity and 71% specificity. This study showed that an increased fQRS-T angle was associated with reverse dipper hypertension in newly diagnosed hypertensive patients without LVH.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.