Osama A Zarzour, F. Orsi, G. Bonomo, P. D. Vigna, G. Mauri, G. Varano
{"title":"Microwave Ablation of Metastatic Lung Lesions Under Guidance of Augmented Reality CT Navigation System (Sirio): A Case Report","authors":"Osama A Zarzour, F. Orsi, G. Bonomo, P. D. Vigna, G. Mauri, G. Varano","doi":"10.4172/1948-5956.1000579","DOIUrl":null,"url":null,"abstract":"Microwave ablation (MWA) of lung lesions under guidance of computed tomography (CT) and SIRIO system (Sistema robotizzato assistito per il puntamento intraoperatorio) is providing accurate and real time visualization system. We present a case of 65 y male patient with multiple metastatic lung lesions from gluteal mesenchymal tumor confirmed histopathologically, MWA of two lesions under general anesthesia using double lumen endotracheal tube to exclude LT lung. Complete ablation of lesions was achieved, post-procedure pneumothorax was treated by (Heimlich valve) insertion, 24 hours follow up revealed complete resolution of pneumothorax. In this case report we found that the total procedure time and the total effective radiation dose of the whole procedure were reduced in compared with a previous case of MW ablation of similar sizes lesions under CT guidance only.","PeriodicalId":15170,"journal":{"name":"Journal of Cancer Science & Therapy","volume":"31 5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cancer Science & Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/1948-5956.1000579","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Microwave ablation (MWA) of lung lesions under guidance of computed tomography (CT) and SIRIO system (Sistema robotizzato assistito per il puntamento intraoperatorio) is providing accurate and real time visualization system. We present a case of 65 y male patient with multiple metastatic lung lesions from gluteal mesenchymal tumor confirmed histopathologically, MWA of two lesions under general anesthesia using double lumen endotracheal tube to exclude LT lung. Complete ablation of lesions was achieved, post-procedure pneumothorax was treated by (Heimlich valve) insertion, 24 hours follow up revealed complete resolution of pneumothorax. In this case report we found that the total procedure time and the total effective radiation dose of the whole procedure were reduced in compared with a previous case of MW ablation of similar sizes lesions under CT guidance only.
在计算机断层扫描(CT)和SIRIO系统(Sistema robotizzato assisto per il puntamento intraoperative)的指导下,肺病变的微波消融(MWA)提供了准确、实时的可视化系统。我们报告一例65岁男性患者,经组织病理学证实为臀部间充质瘤多发转移性肺病变,在全身麻醉下使用双腔气管内管对两个病变进行MWA,以排除LT肺。病灶完全消融,术后气胸经海姆利克氏瓣膜置入术治疗,随访24小时气胸完全消退。在本病例报告中,我们发现与之前仅在CT指导下进行相同大小病变的MW消融相比,整个过程的总手术时间和总有效辐射剂量都减少了。