Determination of Cadmium in Rice by Microwave Digestion and Graphite Furnace Atomic Absorption Spectrometry

Eiko Amakawa, Tsutomu Ogiwara, N. Ohhashi, K. Kamata, Sukeji Suzuki
{"title":"Determination of Cadmium in Rice by Microwave Digestion and Graphite Furnace Atomic Absorption Spectrometry","authors":"Eiko Amakawa, Tsutomu Ogiwara, N. Ohhashi, K. Kamata, Sukeji Suzuki","doi":"10.3358/SHOKUEISHI.41.66","DOIUrl":null,"url":null,"abstract":"An analytical method for cadmium (Cd) in rice by microwave digestion and graphite furnace atomic absorption spectrometry (AAS) was developed. A sample of 0.50g was predigested overnight in 7mL of nitric acid. The mixture was treated with 2mL of hydrogen peroxide solution and immediately exposed to microwave irradiation. The digested solution was evaporated to just before dryness on a hotplate and then made up to 10mL with 0.2% nitric acid. Cd in the sample solution was determined by graphite furnace AAS using a calibration method. 0.5% ammonium dihydrogen phosphate/0.2% nitric acid and 2% ascorbic acid were used as matrix modifiers. Recoveries of Cd added to rice were 97-108%, the CV was 1.6-6.3% and the detection limit was 5ng/g. Cd was detected at 28-96ng/g in polished rice, 18-226ng/g in brown rice and 7-49ng/g in cooked rices.","PeriodicalId":17269,"journal":{"name":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Food Hygienic Society of Japan (shokuhin Eiseigaku Zasshi)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3358/SHOKUEISHI.41.66","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

An analytical method for cadmium (Cd) in rice by microwave digestion and graphite furnace atomic absorption spectrometry (AAS) was developed. A sample of 0.50g was predigested overnight in 7mL of nitric acid. The mixture was treated with 2mL of hydrogen peroxide solution and immediately exposed to microwave irradiation. The digested solution was evaporated to just before dryness on a hotplate and then made up to 10mL with 0.2% nitric acid. Cd in the sample solution was determined by graphite furnace AAS using a calibration method. 0.5% ammonium dihydrogen phosphate/0.2% nitric acid and 2% ascorbic acid were used as matrix modifiers. Recoveries of Cd added to rice were 97-108%, the CV was 1.6-6.3% and the detection limit was 5ng/g. Cd was detected at 28-96ng/g in polished rice, 18-226ng/g in brown rice and 7-49ng/g in cooked rices.
微波消解-石墨炉原子吸收光谱法测定大米中的镉
建立了微波消解-石墨炉原子吸收光谱法测定大米中镉的方法。0.50g的样品在7mL硝酸中预消化过夜。将混合物用2mL双氧水溶液处理后,立即微波照射。将消化后的溶液在热板上蒸发到干燥前,然后用0.2%的硝酸配制成10mL。采用标定法,用石墨炉原子吸收光谱法测定样品溶液中的镉。采用0.5%磷酸二氢铵/0.2%硝酸和2%抗坏血酸作为基体改性剂。加样回收率为97 ~ 108%,CV为1.6 ~ 6.3%,检出限为5ng/g。精米镉含量为28-96ng/g,糙米镉含量为18-226ng/g,熟米镉含量为7-49ng/g。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信