{"title":"Mathematical substantiation technological parameters of device to measure apparent density of porous materials","authors":"Renat H Gainullin, Rishat H Gainullin, E. M. Tsvetkova, M.Y. Smirnov, A. Makarov, A.V. Eroslanov","doi":"10.18698/2542-1468-2022-4-128-134","DOIUrl":null,"url":null,"abstract":"The article describes the procedure for mathematical substantiation technological parameters of a device for measuring the apparent density of porous materials. For this purpose, methods for solving differential equations, Microsoft Excel application with the «Solution Search» function, graphoanalytic and geometric methods were used. The justification was based on the functional dependence Vт/Vc + ΔV1/ΔV2 = 1, describing the relationship between the parameters of the device and the object of study. The use of these methods allowed us to obtain a single result. Calculations have established that the optimal ratio between the volume of the test body and the cylinder for the sample (measuring cylinder) is 0,5. This ratio allows obtaining reliable results in the course of experimental studies, as well as simplifying the measurement procedure. For the study of porous bodies, the sample volume should be selected taking into account the porosity of the material based on a priori information.","PeriodicalId":12343,"journal":{"name":"Forestry Bulletin","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forestry Bulletin","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18698/2542-1468-2022-4-128-134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article describes the procedure for mathematical substantiation technological parameters of a device for measuring the apparent density of porous materials. For this purpose, methods for solving differential equations, Microsoft Excel application with the «Solution Search» function, graphoanalytic and geometric methods were used. The justification was based on the functional dependence Vт/Vc + ΔV1/ΔV2 = 1, describing the relationship between the parameters of the device and the object of study. The use of these methods allowed us to obtain a single result. Calculations have established that the optimal ratio between the volume of the test body and the cylinder for the sample (measuring cylinder) is 0,5. This ratio allows obtaining reliable results in the course of experimental studies, as well as simplifying the measurement procedure. For the study of porous bodies, the sample volume should be selected taking into account the porosity of the material based on a priori information.
多孔材料表观密度测量装置工艺参数的数学证实
本文介绍了一种多孔材料表观密度测量装置工艺参数的数学确定方法。为此,使用了求解微分方程的方法,Microsoft Excel应用程序的«Solution Search»功能,图形分析和几何方法。论证基于函数依赖关系v /Vc + ΔV1/ΔV2 = 1,描述了设备参数与研究对象之间的关系。这些方法的使用使我们得到了一个单一的结果。计算确定试样(测量筒)的试验体体积与筒体体积之比为0,5。该比值允许在实验研究过程中获得可靠的结果,并简化测量程序。对于多孔体的研究,应根据先验信息考虑材料的孔隙率来选择试样体积。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信