S. Haeberle, L. Naegele, R. Burger, R. Zengerle, J. Ducrée
{"title":"Alginate micro-bead fabrication on a centrifugal microfluidics platform","authors":"S. Haeberle, L. Naegele, R. Burger, R. Zengerle, J. Ducrée","doi":"10.1109/MEMSYS.2007.4433113","DOIUrl":null,"url":null,"abstract":"We present a novel method for the direct, centrifugally induced fabrication of small alginate beads displaying adjustable diameters between 180 mum and 800 mum by polymer-tube micronozzles. The size distribution features a CV of 7 - 16 % for the main peak. Up to 600 beads per second and channel are issued from the micronozzle through an air gap towards a standard lab tube (\"Eppi\") attached to the rotor spinning and containing a curing agent. At spinning frequencies between 5 Hz and 28 Hz, the tubes align horizontally under rotation and return to a vertical position as soon as the rotor is at rest. The hardened beads are collected within the tube for further processing or characterization. This method is considered as a low cost technology for micro encapsulation technologies.","PeriodicalId":6388,"journal":{"name":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"1 1","pages":"497-500"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2007.4433113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
We present a novel method for the direct, centrifugally induced fabrication of small alginate beads displaying adjustable diameters between 180 mum and 800 mum by polymer-tube micronozzles. The size distribution features a CV of 7 - 16 % for the main peak. Up to 600 beads per second and channel are issued from the micronozzle through an air gap towards a standard lab tube ("Eppi") attached to the rotor spinning and containing a curing agent. At spinning frequencies between 5 Hz and 28 Hz, the tubes align horizontally under rotation and return to a vertical position as soon as the rotor is at rest. The hardened beads are collected within the tube for further processing or characterization. This method is considered as a low cost technology for micro encapsulation technologies.