A Biodegradable Mesh-Covered Drug Eluting Coronary Embolic Protection Stent: A Promising Solution for Embolization Treatment for Coronary Arteries

Minocha Dr. Pramod Kumar, Kothwala Deveshkumar Mahendralal, Lodha Dikshita Yogendrasinh, D. Samir, Ayush Kumar
{"title":"A Biodegradable Mesh-Covered Drug Eluting Coronary Embolic Protection Stent: A Promising Solution for Embolization Treatment for Coronary Arteries","authors":"Minocha Dr. Pramod Kumar, Kothwala Deveshkumar Mahendralal, Lodha Dikshita Yogendrasinh, D. Samir, Ayush Kumar","doi":"10.18535/ijmsci/v10i7.06","DOIUrl":null,"url":null,"abstract":"\n\n\n \n\n\n \n \n\n\n\nThe newly developed \"Mesh Covered Drug Eluting Coronary Embolic Protection Stent\" is specifically designed to address the problem of distal embolization during percutaneous coronary intervention (PCI), a common procedure for treating myocardial infarction. This study aimed to evaluate the strength of the mesh component in patients with coronary artery disease. The stent system consists of a cobalt-chromium metal stent covered with a knitted mesh made of biodegradable PLGA polymer, which effectively prevents embolic events. The findings of the study demonstrated that the stent system exhibited high radial strength, withstanding significant levels of deformation before failure. This indicates that the mesh covered drug eluting coronary embolic protection stent has the potential to effectively mitigate distal embolization during PCI. The use of a biodegradable mesh in conjunction with the stent offers advantages over traditional stents by reducing the risk of restenosis, thrombosis, and inflammation, thereby improving long-term outcomes. Through bench-scale experiments, we have verified that the \"Mesh Covered Drug Eluting Coronary Embolic Protection Stent\" exhibits robust strength, validating its potential as an effective solution for addressing distal embolization during percutaneous coronary intervention.","PeriodicalId":14151,"journal":{"name":"International Journal Of Medical Science And Clinical Invention","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal Of Medical Science And Clinical Invention","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18535/ijmsci/v10i7.06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

      The newly developed "Mesh Covered Drug Eluting Coronary Embolic Protection Stent" is specifically designed to address the problem of distal embolization during percutaneous coronary intervention (PCI), a common procedure for treating myocardial infarction. This study aimed to evaluate the strength of the mesh component in patients with coronary artery disease. The stent system consists of a cobalt-chromium metal stent covered with a knitted mesh made of biodegradable PLGA polymer, which effectively prevents embolic events. The findings of the study demonstrated that the stent system exhibited high radial strength, withstanding significant levels of deformation before failure. This indicates that the mesh covered drug eluting coronary embolic protection stent has the potential to effectively mitigate distal embolization during PCI. The use of a biodegradable mesh in conjunction with the stent offers advantages over traditional stents by reducing the risk of restenosis, thrombosis, and inflammation, thereby improving long-term outcomes. Through bench-scale experiments, we have verified that the "Mesh Covered Drug Eluting Coronary Embolic Protection Stent" exhibits robust strength, validating its potential as an effective solution for addressing distal embolization during percutaneous coronary intervention.
可生物降解的网状覆盖药物洗脱冠状动脉栓塞保护支架:冠状动脉栓塞治疗的一个有前途的解决方案
新开发的“网状覆盖药物洗脱冠状动脉栓塞保护支架”是专门为解决经皮冠状动脉介入治疗(PCI)中远端栓塞问题而设计的,这是治疗心肌梗死的一种常见方法。本研究旨在评估冠状动脉疾病患者中网状物的强度。支架系统由钴铬金属支架组成,支架上覆盖着可生物降解的PLGA聚合物编织网,可有效防止栓塞事件。研究结果表明,支架系统具有较高的径向强度,在失效前承受显著的变形。这表明网状覆盖药物洗脱冠状动脉栓塞保护支架有可能有效减轻PCI期间远端栓塞。与传统支架相比,生物可降解网状物与支架结合使用具有降低再狭窄、血栓形成和炎症风险的优势,从而改善长期预后。通过实验,我们验证了“网状覆盖药物洗脱冠状动脉栓塞保护支架”具有强大的强度,验证了其作为经皮冠状动脉介入治疗中远端栓塞的有效解决方案的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信