Influence of cooling surface area on indoor air and surface heat transfer characteristics of a thermally activated building system in warm and humid zones: An Experimental study
IF 1.8 4区 工程技术Q3 CONSTRUCTION & BUILDING TECHNOLOGY
{"title":"Influence of cooling surface area on indoor air and surface heat transfer characteristics of a thermally activated building system in warm and humid zones: An Experimental study","authors":"T. Vivek, K. Balaji","doi":"10.1177/17442591231177428","DOIUrl":null,"url":null,"abstract":"Several alternatives have been introduced in recent years to enhance the thermal comfort levels within buildings. Thermally Activated Building Systems (TABS), one of the above alternatives, have gained interest because of the huge benefits this technology offers the building sector. This type of system consists of encapsulated pipes within the building structure to control the surface temperature. This study explores the thermal behavior of the cooling surface and fluctuations in indoor air temperature (IAT) of TABS under various cooling scenarios. Only limited number of investigations has been carried out to study the heat transfer behavior of TABS. Hence, the building indoor thermal properties such as air temperature, surface temperature and rate of heat transfer between the indoor air and inner surface of the TABS has been evaluated experimentally by enhancing the cooling surface area. Moreover the results were compared with the conventional building (no cooling provides). The thermal energy stored in the TABS is significantly removed by the increase in cooling surface area, resulting in a 2°C decrease in the average indoor air temperature. The average heat gain of all wall surfaces in the case of no cooling (WOC) ranges from −3 to 13 W/m2. The amount of heat gain on the walls was not significantly affected by only roof and floor cooling (R+F) activities. Moreover, it ranged from −2 to 24 W/m2 in all surface cooling (ASC) scenarios. As a result, there was additional surface cooling, which increased surface heat gain and indoor cooling capacity.","PeriodicalId":50249,"journal":{"name":"Journal of Building Physics","volume":"9 1","pages":"204 - 229"},"PeriodicalIF":1.8000,"publicationDate":"2023-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Building Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17442591231177428","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1
Abstract
Several alternatives have been introduced in recent years to enhance the thermal comfort levels within buildings. Thermally Activated Building Systems (TABS), one of the above alternatives, have gained interest because of the huge benefits this technology offers the building sector. This type of system consists of encapsulated pipes within the building structure to control the surface temperature. This study explores the thermal behavior of the cooling surface and fluctuations in indoor air temperature (IAT) of TABS under various cooling scenarios. Only limited number of investigations has been carried out to study the heat transfer behavior of TABS. Hence, the building indoor thermal properties such as air temperature, surface temperature and rate of heat transfer between the indoor air and inner surface of the TABS has been evaluated experimentally by enhancing the cooling surface area. Moreover the results were compared with the conventional building (no cooling provides). The thermal energy stored in the TABS is significantly removed by the increase in cooling surface area, resulting in a 2°C decrease in the average indoor air temperature. The average heat gain of all wall surfaces in the case of no cooling (WOC) ranges from −3 to 13 W/m2. The amount of heat gain on the walls was not significantly affected by only roof and floor cooling (R+F) activities. Moreover, it ranged from −2 to 24 W/m2 in all surface cooling (ASC) scenarios. As a result, there was additional surface cooling, which increased surface heat gain and indoor cooling capacity.
期刊介绍:
Journal of Building Physics (J. Bldg. Phys) is an international, peer-reviewed journal that publishes a high quality research and state of the art “integrated” papers to promote scientifically thorough advancement of all the areas of non-structural performance of a building and particularly in heat, air, moisture transfer.