The Effect of Silver Diamine Fluoride on Microleakage and Shear Bond Strength of Glass Ionomer

Dina Hassanen, M. Mostafa, Sarah S. Hashem
{"title":"The Effect of Silver Diamine Fluoride on Microleakage and Shear Bond Strength of Glass Ionomer","authors":"Dina Hassanen, M. Mostafa, Sarah S. Hashem","doi":"10.21608/adjg.2022.54653.1324","DOIUrl":null,"url":null,"abstract":"Purpose: This study was conducted to evaluate the impact of silver diamine fluoride (SDF) on Glass ionomer restoration (Fuji IX) microleakage and shear bond strength. Material and Methods: The present study was carried out on 40 primary extracted human molars. The primary molars were equally divided into 2 groups (Group I, Group II). (Group I) including: 20 primary molars were used for microleakage testing under stereomicroscope at x40. (Group II) including: 20 primary molars were used for shear bond strength testing using Instron Universal Testing Machine. Each group was subdivided into 2 subgroups; subgroup 1 which been treated with SDF then restored by Glass ionomer restoration and subgroup 2 which was restored with Glass ionomer without SDF. Result: In microleakage analysis comparing both groups in both surfaces, the highest mean value was recorded in glass ionomer without SDF group in the occlusal surface (758.77±69.65), followed by glass ionomer without SDF group in the gingival surface (643.74±83.77), then glass ionomer with SDF group in the occlusal surface (126.06±10.70), with the least value was recorded in Glass ionomer with SDF group in the gingival surface (109.12±5.58). In shear bond strength analysis, the higher mean value was recorded in Glass ionomer with SDF group (9.38±1.12), while that recorded in Glass ionomer without SDF group was (1.97±0.16). Conclusion: The results of the current analysis suggest that the use of SDF minimized microleakage and increased intensity of shear bond strength for Glass ionomer restoration.","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"04 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2022.54653.1324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study was conducted to evaluate the impact of silver diamine fluoride (SDF) on Glass ionomer restoration (Fuji IX) microleakage and shear bond strength. Material and Methods: The present study was carried out on 40 primary extracted human molars. The primary molars were equally divided into 2 groups (Group I, Group II). (Group I) including: 20 primary molars were used for microleakage testing under stereomicroscope at x40. (Group II) including: 20 primary molars were used for shear bond strength testing using Instron Universal Testing Machine. Each group was subdivided into 2 subgroups; subgroup 1 which been treated with SDF then restored by Glass ionomer restoration and subgroup 2 which was restored with Glass ionomer without SDF. Result: In microleakage analysis comparing both groups in both surfaces, the highest mean value was recorded in glass ionomer without SDF group in the occlusal surface (758.77±69.65), followed by glass ionomer without SDF group in the gingival surface (643.74±83.77), then glass ionomer with SDF group in the occlusal surface (126.06±10.70), with the least value was recorded in Glass ionomer with SDF group in the gingival surface (109.12±5.58). In shear bond strength analysis, the higher mean value was recorded in Glass ionomer with SDF group (9.38±1.12), while that recorded in Glass ionomer without SDF group was (1.97±0.16). Conclusion: The results of the current analysis suggest that the use of SDF minimized microleakage and increased intensity of shear bond strength for Glass ionomer restoration.
氟化二胺银对玻璃离聚体微漏及剪切粘结强度的影响
目的:研究氟化二胺银(SDF)对玻璃离子修复体(Fuji IX)微渗漏及剪切结合强度的影响。材料与方法:对40颗初生拔除的人磨牙进行研究。将初生磨牙平均分为2组(I组、II组),其中:20颗初生磨牙在x40下体视显微镜下进行微漏检测。(II组)使用Instron万能试验机对20颗初磨牙进行抗剪粘结强度测试。每组再分为2个亚组;第1组用SDF治疗后再用玻璃离聚体修复,第2组用玻璃离聚体修复,但不使用SDF。结果:在两组龈面微渗漏分析中,无SDF组龈面微渗漏平均值最高(758.77±69.65),龈面无SDF组次之(643.74±83.77),龈面有SDF组次之(126.06±10.70),龈面有SDF组最低(109.12±5.58)。在剪切强度分析中,含SDF组的平均值较高(9.38±1.12),不含SDF组的平均值为(1.97±0.16)。结论:目前的分析结果表明,使用SDF可以减少微泄漏,提高玻璃离子修复的剪切结合强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信