{"title":"The influence of deep levels on the admittance of MIS structures with sol-gel TiO2 insulator film","authors":"S. Simeonov, A. Szekeres, I. Minkov, K. Ivanova, M. Gartner, C. Parlog","doi":"10.1109/SMICND.2008.4703390","DOIUrl":null,"url":null,"abstract":"The admittance- voltage characteristics of MIS structures with TiO2(La) dielectric films, have been measured in the 100 Hz-100 kHz test voltage frequency range. It has been established that the dielectric constant of these dielectric films increases with the decrease of the test voltage frequency. The conductance of these MIS structures increases with the test voltage frequency in the same 100 Hz-100 kHz frequency range. These admittance measurements are used to estimate the density of deep levels, responsible for observed dependence of the dielectric constant on the test voltage frequency in investigated MIS structures.","PeriodicalId":6406,"journal":{"name":"2008 IEEE International Conference on Semiconductor Electronics","volume":"75 1","pages":"237-240"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE International Conference on Semiconductor Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMICND.2008.4703390","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The admittance- voltage characteristics of MIS structures with TiO2(La) dielectric films, have been measured in the 100 Hz-100 kHz test voltage frequency range. It has been established that the dielectric constant of these dielectric films increases with the decrease of the test voltage frequency. The conductance of these MIS structures increases with the test voltage frequency in the same 100 Hz-100 kHz frequency range. These admittance measurements are used to estimate the density of deep levels, responsible for observed dependence of the dielectric constant on the test voltage frequency in investigated MIS structures.
深层能级对溶胶-凝胶TiO2绝缘体膜MIS结构导纳的影响
在100hz ~ 100khz的测试电压频率范围内,测量了TiO2(La)介质膜的MIS结构的导纳-电压特性。结果表明,随着测试电压频率的降低,这些介质膜的介电常数增大。在相同的100hz - 100khz频率范围内,这些MIS结构的电导随测试电压频率的增加而增加。这些导纳测量用于估计深能级的密度,负责观察到介电常数对所研究的MIS结构的测试电压频率的依赖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信