Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

IF 0.4 Q4 SPECTROSCOPY
Yeoun Hur, Sookil Tae, Yun-Joo Koh, S. Hong, Y. H. Yoon, H. Jang, Sooji Kim, K. Kim, S. Kang, Young-Shin Lee, S. Han
{"title":"Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry","authors":"Yeoun Hur, Sookil Tae, Yun-Joo Koh, S. Hong, Y. H. Yoon, H. Jang, Sooji Kim, K. Kim, S. Kang, Young-Shin Lee, S. Han","doi":"10.5478/MSL.2014.5.2.42","DOIUrl":null,"url":null,"abstract":"A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI- MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphy- rin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm × 2.0 mm, 4 µm) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/ v) at a flow rate of 450 µL/min. Porphyrins and the internal standard (IS), coproporphyrin I- 15 N4, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensi- tivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recov- ery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.","PeriodicalId":18238,"journal":{"name":"Mass Spectrometry Letters","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2014-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass Spectrometry Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5478/MSL.2014.5.2.42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 2

Abstract

A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI- MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphy- rin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm × 2.0 mm, 4 µm) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/ v) at a flow rate of 450 µL/min. Porphyrins and the internal standard (IS), coproporphyrin I- 15 N4, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensi- tivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recov- ery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.
高效液相色谱-串联质谱法同时测定人体尿液和血浆中的5种卟啉类化合物
建立了一种高效、灵敏的液相色谱-电喷雾串联质谱(LC-ESI- MS/MS)同时定量测定人血浆和尿液中卟啉(共比例卟啉、五羧基卟啉、六羧基卟啉、七羧基卟啉和uroporphyin)的方法。酸化血浆样品和尿液样品分别采用乙酸乙酯液液萃取和乙腈蛋白沉淀制备。在Synergi Fusion RP柱(150 mm × 2.0 mm, 4µm)上进行分离,流动相a(0.1%甲酸/ 2 mmol/L乙酸铵,v/v)和流动相B(20%甲醇/乙腈,v/v)以450µL/min的流速梯度洗脱。采用电喷雾离子源为正离子模式的串联质谱仪对卟啉和内标物coproporphyrin I- 15n4进行了检测。优化了质子化前体离子和相关产物离子的多反应监测(MRM)跃迁,以提高选择性和灵敏度。通过选择性、线性、定量限(LOQ)、精密度、准确度、回收率和稳定性等指标对该方法进行了验证。标定曲线在0.1 ~ 100 nmol/L范围内,所有卟啉的定量限均为0.1 nmol/L。结果表明,该方法具有良好的准确度、精密度、回收率和稳定性。最后,将该方法成功应用于203例韩国儿童自闭症谱系障碍(ASD)诊断的临床研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
20.00%
发文量
0
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信