Correction of motion artifact in cardiac optical mapping using image registration technique

G.K. Rohde, V. Sidorov, A. Aldroubi, B. Dawant, Shien‐Fong Lin
{"title":"Correction of motion artifact in cardiac optical mapping using image registration technique","authors":"G.K. Rohde, V. Sidorov, A. Aldroubi, B. Dawant, Shien‐Fong Lin","doi":"10.1109/IEMBS.2002.1106437","DOIUrl":null,"url":null,"abstract":"Myocardial contraction causes motion artifact in cardiac optical recording. Mechanical and chemical methods have been used, both with significant limitations, to reduce motion artifact in optical mapping. We propose an image registration approach using mutual information between image frames to solve this problem. The algorithm was tested with optical mapping data from isolated, perfused rabbit hearts. Both affine and nonrigid registration methods reduced motion artifact as measured by a reduction in excessive positive and negative deflection in the optical potential traces after the registration process. Such an approach could be further developed for real-time, in vivo electrophysiological measurement.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":"27 1","pages":"1375-1376 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1106437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Myocardial contraction causes motion artifact in cardiac optical recording. Mechanical and chemical methods have been used, both with significant limitations, to reduce motion artifact in optical mapping. We propose an image registration approach using mutual information between image frames to solve this problem. The algorithm was tested with optical mapping data from isolated, perfused rabbit hearts. Both affine and nonrigid registration methods reduced motion artifact as measured by a reduction in excessive positive and negative deflection in the optical potential traces after the registration process. Such an approach could be further developed for real-time, in vivo electrophysiological measurement.
利用图像配准技术校正心脏光学成像中的运动伪影
心脏光学记录中心肌收缩引起运动伪影。机械和化学方法已被用于减少光学测绘中的运动伪影,但两者都有很大的局限性。我们提出了一种利用图像帧间互信息的图像配准方法来解决这一问题。该算法用离体灌注兔心脏的光学映射数据进行了测试。仿射和非刚性配准方法都减少了运动伪影,这是通过在配准过程后光学势迹中过度的正负偏转的减少来测量的。这种方法可以进一步用于实时的体内电生理测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
368
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信