A Fraction Trapping and Transfer Device for the Analysis of Cigarette Smoke

Q3 Agricultural and Biological Sciences
J. Graham
{"title":"A Fraction Trapping and Transfer Device for the Analysis of Cigarette Smoke","authors":"J. Graham","doi":"10.2478/cttr-2013-0215","DOIUrl":null,"url":null,"abstract":"Abstract The device described has been developed in order to provide a separation of smoke condensate volatiles (B. Pt. range 50°-350°C) adequate for qualitative and quantitative analysis. The various disadvantages of the use of a single GLC column for this purpose are avoided by the use of a two-stage GLC process. Fractions are trapped from a primary column chromatogram, and transferred to a secondary column of different polarity, where a further separation is obtained. The processes of trapping and transfer are electronically controlled, and permit quantitative transfer of any fraction between the two columns, which are run under completely independent conditions. Examples of the separation obtained with cigarette smoke 'semi-volatiles' and also with vapour phase are given.","PeriodicalId":35431,"journal":{"name":"Beitrage zur Tabakforschung International/ Contributions to Tobacco Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1969-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Beitrage zur Tabakforschung International/ Contributions to Tobacco Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/cttr-2013-0215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The device described has been developed in order to provide a separation of smoke condensate volatiles (B. Pt. range 50°-350°C) adequate for qualitative and quantitative analysis. The various disadvantages of the use of a single GLC column for this purpose are avoided by the use of a two-stage GLC process. Fractions are trapped from a primary column chromatogram, and transferred to a secondary column of different polarity, where a further separation is obtained. The processes of trapping and transfer are electronically controlled, and permit quantitative transfer of any fraction between the two columns, which are run under completely independent conditions. Examples of the separation obtained with cigarette smoke 'semi-volatiles' and also with vapour phase are given.
一种用于香烟烟雾分析的馏分捕获和传递装置
该装置是为了提供足够的烟冷凝水挥发物分离(B. pt范围50°-350°C)进行定性和定量分析而开发的。使用两级GLC过程可以避免使用单个GLC柱的各种缺点。从一级色谱柱中捕获馏分,并转移到不同极性的二级色谱柱,在那里获得进一步的分离。捕获和转移的过程是电子控制的,并允许在完全独立的条件下运行的两列之间的任何分数的定量转移。给出了用香烟烟雾“半挥发物”和气相进行分离的例子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Beitrage zur Tabakforschung International/ Contributions to Tobacco Research
Beitrage zur Tabakforschung International/ Contributions to Tobacco Research Agricultural and Biological Sciences-Agronomy and Crop Science
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信