Office Building Envelope Design Optimization by Modified Competitive Search Algorithm for Energy Saving

Q1 Mathematics
Engineered Science Pub Date : 2023-01-01 DOI:10.30919/es953
T. Jearsiripongkul, M. Karbasforoushha, M. Khajehzadeh, S. Keawsawasvong, C. Thongchom
{"title":"Office Building Envelope Design Optimization by Modified Competitive Search Algorithm for Energy Saving","authors":"T. Jearsiripongkul, M. Karbasforoushha, M. Khajehzadeh, S. Keawsawasvong, C. Thongchom","doi":"10.30919/es953","DOIUrl":null,"url":null,"abstract":"35 Building envelopes for green buildings should be designed with low energy consumption and low 36 construction costs. A modified competitive search algorithm is used for the optimization of the office 37 building design due to the long runtime of simulation tools such as EnergyPlus and TRNSYS. For the 38 minimization of the cost of construction at the needed energy conservation, the envelope configuration, 39 such as window numbers, walls, glass curtain walls, etc., is optimized. Comparing the proposed algorithm 40 with some others, the cost decreased for the optimum design of the building structure at the needed energy 41 load value. The number of iterations is also reduced by the proposed approach. Moreover, the overall area 42 of the window is increased, which has resulted in the natural ventilation being more proper. Since the ratio 43 of the glass curtain wall is increased, it can result that the indoor lighting being better. Per unit area of the 44 envelope, the value of the energy load is smaller and the total cost is lower for the proposed method in 45 comparison with other algorithms, considering that the opening rate of the window is much the same. The 46 total cost decreased by 37.1% in comparison with the initial design. It can be observed that the MCSA is 47 more efficient than the other compared methods in energy saving of the building in this paper. 48","PeriodicalId":36059,"journal":{"name":"Engineered Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineered Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30919/es953","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 1

Abstract

35 Building envelopes for green buildings should be designed with low energy consumption and low 36 construction costs. A modified competitive search algorithm is used for the optimization of the office 37 building design due to the long runtime of simulation tools such as EnergyPlus and TRNSYS. For the 38 minimization of the cost of construction at the needed energy conservation, the envelope configuration, 39 such as window numbers, walls, glass curtain walls, etc., is optimized. Comparing the proposed algorithm 40 with some others, the cost decreased for the optimum design of the building structure at the needed energy 41 load value. The number of iterations is also reduced by the proposed approach. Moreover, the overall area 42 of the window is increased, which has resulted in the natural ventilation being more proper. Since the ratio 43 of the glass curtain wall is increased, it can result that the indoor lighting being better. Per unit area of the 44 envelope, the value of the energy load is smaller and the total cost is lower for the proposed method in 45 comparison with other algorithms, considering that the opening rate of the window is much the same. The 46 total cost decreased by 37.1% in comparison with the initial design. It can be observed that the MCSA is 47 more efficient than the other compared methods in energy saving of the building in this paper. 48
基于改进竞争搜索算法的办公楼围护结构节能优化
绿色建筑的围护结构应设计成低能耗、低造价的建筑。针对EnergyPlus、TRNSYS等仿真工具运行时间较长的问题,采用改进的竞争搜索算法对37号办公大楼设计进行优化。为了在节约能源的同时最大限度地降低建筑成本,围护结构的配置,如窗户数量、墙壁、玻璃幕墙等都进行了优化。将所提算法与其他算法进行比较,降低了建筑结构在所需能量负荷值下的优化设计成本。该方法还减少了迭代次数。此外,窗户的整体面积增加了,这使得自然通风更加适当。由于增加了玻璃幕墙的比例43,可以使室内采光更好。在44包络线的单位面积上,考虑到开窗率基本相同的情况下,与其他算法相比,本文方法在45中的能量负荷值更小,总成本更低。与最初的设计相比,46的总成本降低了37.1%。可以观察到,MCSA在建筑节能方面的效率比本文所比较的其他方法高47%。48
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Engineered Science
Engineered Science Mathematics-Applied Mathematics
CiteScore
14.90
自引率
0.00%
发文量
83
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信