Validation of an Et-Aas Method for the Determination of Pb and Cd in Liver and Kidney Samples of Brown Hare (Lepus Europaeus P.)

D. Beuković
{"title":"Validation of an Et-Aas Method for the Determination of Pb and Cd in Liver and Kidney Samples of Brown Hare (Lepus Europaeus P.)","authors":"D. Beuković","doi":"10.2461/WBP.2015.11.7","DOIUrl":null,"url":null,"abstract":"A rapid, sensitive, accurate and precise method for the determination of lead and cadmium in tissue samples of hare by Electro-thermal Atomic Absorption Spectrometry was validated. The main parameters evaluated in the validation were: linearity, accuracy, repeatability and within-laboratory reproducibility, detection and quantification limits. The results for limit of detection and limit of quantification were 4.26 and 12.90 µg/kg for lead and for cadmium were 2.32 and 7.04 µg/kg. Method showed good linearity R2=0,997 for cadmium and R2=0,999 for lead. Accuracy was evaluated by spike recovery tests and it was performed for lead and cadmium in both, kidney and liver samples. Obtained recovery values were ranged from 81.6% to 107.0%. Overall measure uncertainties were 33% for lead and 29% for cadmium. The results make evident that the procedure can be used as a method for the determination of lead and cadmium in liver and kidney samples of brown hare.","PeriodicalId":89522,"journal":{"name":"Wildlife biology in practice (Online)","volume":"22 1","pages":"63-69"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wildlife biology in practice (Online)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2461/WBP.2015.11.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A rapid, sensitive, accurate and precise method for the determination of lead and cadmium in tissue samples of hare by Electro-thermal Atomic Absorption Spectrometry was validated. The main parameters evaluated in the validation were: linearity, accuracy, repeatability and within-laboratory reproducibility, detection and quantification limits. The results for limit of detection and limit of quantification were 4.26 and 12.90 µg/kg for lead and for cadmium were 2.32 and 7.04 µg/kg. Method showed good linearity R2=0,997 for cadmium and R2=0,999 for lead. Accuracy was evaluated by spike recovery tests and it was performed for lead and cadmium in both, kidney and liver samples. Obtained recovery values were ranged from 81.6% to 107.0%. Overall measure uncertainties were 33% for lead and 29% for cadmium. The results make evident that the procedure can be used as a method for the determination of lead and cadmium in liver and kidney samples of brown hare.
et -原子吸收光谱法测定褐兔肝脏和肾脏中铅和镉的验证
建立了一种快速、灵敏、准确、精密度高的电热原子吸收光谱法测定兔组织样品中铅和镉的方法。验证中评估的主要参数有:线性度、准确度、重复性和实验室内重现性、检测限和定量限。铅的检出限和定量限分别为4.26和12.90µg/kg,镉的检出限和定量限分别为2.32和7.04µg/kg。方法对镉和铅的线性关系良好,R2= 0.997, R2= 0.999。通过尖峰回收率测试评估准确性,并对肾脏和肝脏样品中的铅和镉进行了测试。回收率为81.6% ~ 107.0%。铅和镉的总体测量不确定度分别为33%和29%。结果表明,该方法可作为测定褐兔肝脏和肾脏中铅和镉的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信