{"title":"Evaluation of CMUT Performance Under Different Excitation Signals and Electrode Coverage","authors":"A. Yasar, Fikret Yildiz, O. Eroğul","doi":"10.23919/ELECO47770.2019.8990518","DOIUrl":null,"url":null,"abstract":"CMUT output characteristics with different top electrode coverages were investigated by driving different excitation signals. Membrane displacements were obtained using a Simulink model. Membrane displacements were examined for three cases of electrode coverage, one-quarter, half and entire of the membrane area. The diameter and thickness of the CMUT membrane used in the simulation were 60 pm and 2.6 pm. First, the collapse voltages were found by using numerical calculations. Then these values were analyzed using the Simulink model. It was understood that electrode coverage affected the collapse voltage of CMUT. After that, analyzes were made for AC signals of different types (sawtooth, sine, and square) and different amplitudes DC bias voltages and AC excitation signals. Our results showed that CMUT has the highest displacement in the case of 100% electrode coverage when excited in square signal is used.","PeriodicalId":6611,"journal":{"name":"2019 11th International Conference on Electrical and Electronics Engineering (ELECO)","volume":"21 1","pages":"441-444"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 11th International Conference on Electrical and Electronics Engineering (ELECO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ELECO47770.2019.8990518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

CMUT output characteristics with different top electrode coverages were investigated by driving different excitation signals. Membrane displacements were obtained using a Simulink model. Membrane displacements were examined for three cases of electrode coverage, one-quarter, half and entire of the membrane area. The diameter and thickness of the CMUT membrane used in the simulation were 60 pm and 2.6 pm. First, the collapse voltages were found by using numerical calculations. Then these values were analyzed using the Simulink model. It was understood that electrode coverage affected the collapse voltage of CMUT. After that, analyzes were made for AC signals of different types (sawtooth, sine, and square) and different amplitudes DC bias voltages and AC excitation signals. Our results showed that CMUT has the highest displacement in the case of 100% electrode coverage when excited in square signal is used.
不同激励信号和电极覆盖下CMUT性能评价
通过驱动不同的激励信号,研究了不同顶电极覆盖率下CMUT的输出特性。使用Simulink模型获得膜位移。膜位移检查了三种情况下电极覆盖,四分之一,一半和整个膜面积。模拟中使用的CMUT膜直径为60 pm,厚度为2.6 pm。首先,通过数值计算找到了坍塌电压。然后使用Simulink模型对这些值进行分析。电极覆盖对CMUT的坍塌电压有影响。然后,对不同类型的交流信号(锯齿、正弦、平方)和不同幅值的直流偏置电压和交流励磁信号进行分析。结果表明,在电极覆盖率为100%的情况下,CMUT在方波激励下的位移最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信