Glassy carbon electrode modified with ex-in-situ gold film – A simple and effective working electrode for As(III) determination by using differential pulse anodic stripping voltammetry

Hoang Thai Long, T. Le
{"title":"Glassy carbon electrode modified with ex-in-situ gold film – A simple and effective working electrode for As(III) determination by using differential pulse anodic stripping voltammetry","authors":"Hoang Thai Long, T. Le","doi":"10.26459/hueunijns.v130i1d.6459","DOIUrl":null,"url":null,"abstract":"An easy-to-make new working electrode, an ex-in-situ AuF/GCE, was developed for trace As(III) detection. A gold film electrode prepared ex-situ was re-plated in-situ during each arsenic deposition step by adding Au(III) into the analyte solution. The factors affecting arsenic stripping response, namely, gold film preparation conditions, electrolyte concentration, electrode cleaning potential, cleaning time, deposition potential, and deposition time, were investigated. Compared with the traditional gold film electrodes prepared ex-situ, the new electrode has better precision and linearity of arsenic differential pulse anodic stripping voltammetry responses. For a deposition time of 90 s at –200 mV, the new electrode exhibits a sensitivity, a limit of detection (3-Sigma), a limit of quantitation of 0.103 μA·L·μg–1, 0.4 μg·L–1, and 1.3 μg·L–1, respectively.","PeriodicalId":13004,"journal":{"name":"Hue University Journal of Science: Natural Science","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hue University Journal of Science: Natural Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26459/hueunijns.v130i1d.6459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An easy-to-make new working electrode, an ex-in-situ AuF/GCE, was developed for trace As(III) detection. A gold film electrode prepared ex-situ was re-plated in-situ during each arsenic deposition step by adding Au(III) into the analyte solution. The factors affecting arsenic stripping response, namely, gold film preparation conditions, electrolyte concentration, electrode cleaning potential, cleaning time, deposition potential, and deposition time, were investigated. Compared with the traditional gold film electrodes prepared ex-situ, the new electrode has better precision and linearity of arsenic differential pulse anodic stripping voltammetry responses. For a deposition time of 90 s at –200 mV, the new electrode exhibits a sensitivity, a limit of detection (3-Sigma), a limit of quantitation of 0.103 μA·L·μg–1, 0.4 μg·L–1, and 1.3 μg·L–1, respectively.
原原位金膜修饰玻碳电极-差分脉冲阳极溶出伏安法测定砷(III)的一种简单有效的工作电极
开发了一种易于制作的新型工作电极,即前原位AuF/GCE,用于痕量As(III)的检测。在每个砷沉积步骤中,通过在分析物溶液中加入Au(III),原位重新镀上原位制备的金膜电极。考察了金膜制备条件、电解液浓度、电极清洗电位、清洗时间、沉积电位、沉积时间等因素对砷溶出响应的影响。与原位制备的传统金膜电极相比,该电极具有更好的砷差分脉冲阳极溶出伏安响应精度和线性度。在-200 mV下沉积90 s,电极的灵敏度、检测限(3 σ)和定量限分别为0.103 μA·L·L - 1、0.4 μg·L - 1和1.3 μg·L - 1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信