Design of sensor setup and study of humidity sensing behaviour of conducting polyaniline / ceramic composites

T. Machappa, K. Anilkumar, M. Sasikala, M. A. Ambika Prasad
{"title":"Design of sensor setup and study of humidity sensing behaviour of conducting polyaniline / ceramic composites","authors":"T. Machappa, K. Anilkumar, M. Sasikala, M. A. Ambika Prasad","doi":"10.1109/ICSENST.2008.4757114","DOIUrl":null,"url":null,"abstract":"Sensor setup for the measurement of humidity was designed using square glass chamber provided with sample holder, vaporizer, hygrometer and temperature display. Using this set up, authors have studied the response time of the sensor setup and humidity sensing properties for Polyaniline (PANI) and PANI/sodium metavanadate (NaVO3) composites. The variation in electrical resistance with change in relative humidity (RH) in the range between 20 to 95% of RH is reported and this may be due to change in surface electrical resistance. The variation in resistance and hence conductivity depends on capillary condensation of water causing ionic conductivity within the sensing materials.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"1 1","pages":"284-288"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Sensor setup for the measurement of humidity was designed using square glass chamber provided with sample holder, vaporizer, hygrometer and temperature display. Using this set up, authors have studied the response time of the sensor setup and humidity sensing properties for Polyaniline (PANI) and PANI/sodium metavanadate (NaVO3) composites. The variation in electrical resistance with change in relative humidity (RH) in the range between 20 to 95% of RH is reported and this may be due to change in surface electrical resistance. The variation in resistance and hence conductivity depends on capillary condensation of water causing ionic conductivity within the sensing materials.
导电聚苯胺/陶瓷复合材料传感器装置设计及湿度传感性能研究
采用方形玻璃腔设计了湿度测量传感器装置,并配有样品架、蒸发器、湿度计和温度显示器。利用该装置,研究了聚苯胺(PANI)和聚苯胺/偏氰酸钠(NaVO3)复合材料传感器设置的响应时间和湿度传感性能。据报道,电阻随相对湿度(RH)变化的变化范围在RH的20%至95%之间,这可能是由于表面电阻的变化。电阻和电导率的变化取决于在传感材料内引起离子电导率的水的毛细凝结。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信