Yonezawa Yasuto, K. Aoki, Takumi Ito, Changhoon Choi
{"title":"Study on Ultimate State and Mechanical Characteristics of Connection Joint of Damaged H-Shaped Bracing Structure","authors":"Yonezawa Yasuto, K. Aoki, Takumi Ito, Changhoon Choi","doi":"10.4172/2165-784X.1000286","DOIUrl":null,"url":null,"abstract":"In Japan, various kinds of failure modes in steel structures have been reported in severe past earthquake disasters. Also, the various type of repair method for damaged building structure is suggested, and it has been published as restoration manual and guideline. However, it is guessed that these repair methods have some difficulties related to construction technique and estimation of recovery of seismic resistant performance after repair. This study focuses on the seismic ultimate state of steel brace connection of original state and repaired state after damaged, and the effective restoration method is suggested herein. In our past researches, new repairing method for damaged steel bracing joint which has angle-section brace member has been suggested already, and its applicability and feasibility were investigated experimentally. Herein, H- shaped section brace members are focused which are adopted on middle-rise or high-rise steel building structures, and also, various kinds of failure modes of these bracing structure has been reported after past terrible seismic disasters in Japan. So, the effective restoration method is proposed here. First, to reproduce the seismic ultimate state, the vertical loading test on H-shaped bracing test specimen are performed as parameters with bolt layout, thickness of gusset plate, that is, out-of-plane rigidity of joint. Next, the damaged bracing joints are repaired. Finally, the loading test is done on repaired specimen again. From test results, the restoring force characteristics after repair can be recovered, and any type of failure modes are observed. So, 3D model of damaged bracing joint is constructed by using 3D scanner, and it helps to identify the failure mode and yield lines on gusset plate. Furthermore, the plastic limit analysis is performed by reference of 3D model, and it can predict the ultimate state of test results well.","PeriodicalId":52256,"journal":{"name":"Tumu yu Huanjing Gongcheng Xuebao/Journal of Civil and Environmental Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tumu yu Huanjing Gongcheng Xuebao/Journal of Civil and Environmental Engineering","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.4172/2165-784X.1000286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
In Japan, various kinds of failure modes in steel structures have been reported in severe past earthquake disasters. Also, the various type of repair method for damaged building structure is suggested, and it has been published as restoration manual and guideline. However, it is guessed that these repair methods have some difficulties related to construction technique and estimation of recovery of seismic resistant performance after repair. This study focuses on the seismic ultimate state of steel brace connection of original state and repaired state after damaged, and the effective restoration method is suggested herein. In our past researches, new repairing method for damaged steel bracing joint which has angle-section brace member has been suggested already, and its applicability and feasibility were investigated experimentally. Herein, H- shaped section brace members are focused which are adopted on middle-rise or high-rise steel building structures, and also, various kinds of failure modes of these bracing structure has been reported after past terrible seismic disasters in Japan. So, the effective restoration method is proposed here. First, to reproduce the seismic ultimate state, the vertical loading test on H-shaped bracing test specimen are performed as parameters with bolt layout, thickness of gusset plate, that is, out-of-plane rigidity of joint. Next, the damaged bracing joints are repaired. Finally, the loading test is done on repaired specimen again. From test results, the restoring force characteristics after repair can be recovered, and any type of failure modes are observed. So, 3D model of damaged bracing joint is constructed by using 3D scanner, and it helps to identify the failure mode and yield lines on gusset plate. Furthermore, the plastic limit analysis is performed by reference of 3D model, and it can predict the ultimate state of test results well.