{"title":"Comparative Assessment of the Analytical Parameters in Ascorbic Acid and Sulphite Assay at a Spectrographic Carbon Working Electrode","authors":"A. Pisoschi, A. Pop","doi":"10.2478/alife-2018-0072","DOIUrl":null,"url":null,"abstract":"Abstract The aim of this study is the comparative investigation of spectrographic carbon electrode’s viability as working electrode, in ascorbic acid and sulphite asssessment. Cyclic voltammetry involves a linear sweeping of the potential, the analytical signal being represented by the anodic oxidation /cathodic reduction peak of the analyte. For both analytes, the electro-oxidation resulted in an anodic peak, correlable with ascorbic acid / sulphite concentration. The analytical range of linear response corresponded to 0.07 - 10 mM for ascorbic acid and to 15.5 mg/L - 4 g/L for sulphite. The relative standard deviation RSD (%) was 2.71 % for ascorbic acid and 2.88 % for sulphite. The sensitivities, given by the slopes of the calibration graphs were 88.88 μA/mmole/L for ascorbic acid and 477.37 μA/g/L for sulphite.","PeriodicalId":6413,"journal":{"name":"“Agriculture for Life, Life for Agriculture” Conference Proceedings","volume":"2010 1","pages":"465 - 469"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"“Agriculture for Life, Life for Agriculture” Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/alife-2018-0072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Abstract The aim of this study is the comparative investigation of spectrographic carbon electrode’s viability as working electrode, in ascorbic acid and sulphite asssessment. Cyclic voltammetry involves a linear sweeping of the potential, the analytical signal being represented by the anodic oxidation /cathodic reduction peak of the analyte. For both analytes, the electro-oxidation resulted in an anodic peak, correlable with ascorbic acid / sulphite concentration. The analytical range of linear response corresponded to 0.07 - 10 mM for ascorbic acid and to 15.5 mg/L - 4 g/L for sulphite. The relative standard deviation RSD (%) was 2.71 % for ascorbic acid and 2.88 % for sulphite. The sensitivities, given by the slopes of the calibration graphs were 88.88 μA/mmole/L for ascorbic acid and 477.37 μA/g/L for sulphite.