{"title":"Calibration of a Digital Current Transformer Measuring Bridge: Metrological Challenges and Uncertainty Contributions","authors":"G. Frigo, M. Agustoni","doi":"10.3390/metrology1020007","DOIUrl":null,"url":null,"abstract":"In this paper, we consider the calibration of measuring bridges for non-conventional instrument transformers with digital output. In this context, the main challenge is represented by the necessity of synchronization between analog and digital outputs. To this end, we propose a measurement setup that allows for monitoring and quantifying the main quantities of interest. A possible laboratory implementation is presented and the main sources of uncertainty are discussed. From a metrological point of view, technical specifications and statistical analysis are employed to draw up a rigorous uncertainty budget of the calibration setup. An experimental validation is also provided through the thorough characterization of the measurement accuracy of a commercial device in use at METAS laboratories. The proposed analysis proves how the calibration of measuring bridges for non-conventional instrument transformers requires ad hoc measurement setups and identifies possible space for improvement, particularly in terms of outputs’ synchronization and flexibility of the generation process.","PeriodicalId":100666,"journal":{"name":"Industrial Metrology","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial Metrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/metrology1020007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
In this paper, we consider the calibration of measuring bridges for non-conventional instrument transformers with digital output. In this context, the main challenge is represented by the necessity of synchronization between analog and digital outputs. To this end, we propose a measurement setup that allows for monitoring and quantifying the main quantities of interest. A possible laboratory implementation is presented and the main sources of uncertainty are discussed. From a metrological point of view, technical specifications and statistical analysis are employed to draw up a rigorous uncertainty budget of the calibration setup. An experimental validation is also provided through the thorough characterization of the measurement accuracy of a commercial device in use at METAS laboratories. The proposed analysis proves how the calibration of measuring bridges for non-conventional instrument transformers requires ad hoc measurement setups and identifies possible space for improvement, particularly in terms of outputs’ synchronization and flexibility of the generation process.