{"title":"Assessment of Air Quality Perception and Its Effects on Users’ Thermal Comfort in Office Buildings","authors":"Candi Citadini de Oliveira, R. F. Rupp, E. Ghisi","doi":"10.20944/PREPRINTS202106.0324.V1","DOIUrl":null,"url":null,"abstract":"Since people spend most of their time in indoor environments, the objective of this work was to study indoor air quality perception and its effects on users’ thermal comfort. Based on previous data from a building with a central air-conditioning system and two mixed-mode buildings located in the humid subtropical climate of Florianópolis, southern Brazil, statistical analyses were performed. Each user subjective answer obtained through a questionnaire was combined with the corresponding environmental conditions – measured using microclimate stations, a portable thermo-anemometer and a CO2 analyser. Results showed that improvement in air quality was associated with the reduction of air temperature and humidity ratio. Also, there was a significant influence of thermal, air movement and humidity sensation and acceptability of air quality perception. Users felt more satisfied or neutral with air quality for being in thermal comfort, and not because of the CO2 level – which means that air quality perception is influenced by factors other than CO2. This study recommends the implementation of an air exchange device in split air-conditioners with air recirculation used in mixed-mode buildings in Brazil. It is important to provide suitable indoor ventilation to reduce pollutants concentration, ensure good air quality and prevent respiratory diseases.","PeriodicalId":10987,"journal":{"name":"Decis. Sci.","volume":"103 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Decis. Sci.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20944/PREPRINTS202106.0324.V1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Since people spend most of their time in indoor environments, the objective of this work was to study indoor air quality perception and its effects on users’ thermal comfort. Based on previous data from a building with a central air-conditioning system and two mixed-mode buildings located in the humid subtropical climate of Florianópolis, southern Brazil, statistical analyses were performed. Each user subjective answer obtained through a questionnaire was combined with the corresponding environmental conditions – measured using microclimate stations, a portable thermo-anemometer and a CO2 analyser. Results showed that improvement in air quality was associated with the reduction of air temperature and humidity ratio. Also, there was a significant influence of thermal, air movement and humidity sensation and acceptability of air quality perception. Users felt more satisfied or neutral with air quality for being in thermal comfort, and not because of the CO2 level – which means that air quality perception is influenced by factors other than CO2. This study recommends the implementation of an air exchange device in split air-conditioners with air recirculation used in mixed-mode buildings in Brazil. It is important to provide suitable indoor ventilation to reduce pollutants concentration, ensure good air quality and prevent respiratory diseases.
办公建筑空气质量感知评价及其对用户热舒适的影响
由于人们大部分时间都在室内环境中度过,因此本研究的目的是研究室内空气质量感知及其对用户热舒适的影响。根据位于巴西南部Florianópolis湿润亚热带气候的一座带有中央空调系统的建筑和两座混合模式建筑的先前数据,进行了统计分析。通过问卷调查获得的每个用户的主观答案与相应的环境条件相结合-使用小气候站,便携式温度风速计和二氧化碳分析仪进行测量。结果表明,空气质量的改善与空气温湿度比的降低有关。此外,热感觉、空气运动和湿度感觉以及空气质量感知的可接受性也有显著影响。用户对热舒适的空气质量感到更满意或中性,而不是因为二氧化碳水平-这意味着空气质量感知受二氧化碳以外的因素影响。本研究建议在巴西混合模式建筑中使用的带有空气再循环的分体式空调中实施空气交换装置。提供适当的室内通风对于降低污染物浓度,确保良好的空气质量和预防呼吸系统疾病非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信