Comparative analysis of ELISA, FEIA and CLIA techniques in diagnostic immunoassays for thyroid stimulating hormone: A cross-sectional study form Morang, Nepal

R. L. Mallick, C. P. Gaire
{"title":"Comparative analysis of ELISA, FEIA and CLIA techniques in diagnostic immunoassays for thyroid stimulating hormone: A cross-sectional study form Morang, Nepal","authors":"R. L. Mallick, C. P. Gaire","doi":"10.3126/jbs.v10i1.57050","DOIUrl":null,"url":null,"abstract":"Background: TSH and circulating thyroid hormones are measured in serum as part of a thyroid function test (TFT), which evaluates the thyroid gland's ability to produce and regulate thyroid hormones. The objective of the current study was to compare the technical performance between ELISA, FEIA and the currently marketed automated CLIA for measuring the TSH level. \nMaterial and methods: A total of 1,200 participants were enrolled in the study. Subjects were chosen randomly, either OPD patients or inpatients of Birat Medical College Teaching Hospital. Chemiluminescence Immunoassay (CLIA), Enzyme-linked Immunoassay (ELISA) and Fluorometric Enzyme Immunoassay (FEIA) technologies were performed. \nResults: The total number of patients (1200) was categorized into group I, normal TSH (n = 680); group II, elevated TSH (n = 300); and group III, decreased TSH (n = 220). CLIA and FEIA based results were significantly more sensitive compared to ELISA results for TSH detection. \nConclusion: Chemiluminescence assay system, when compared to FEIA and ELISA, is far superior in terms of accuracy and sensitivity for reporting both subnormal and above normal TSH levels and can be helpful in the detection of subclinical thyroid dysfunction (SCTD) and in the screening of thyroid diseases.","PeriodicalId":7690,"journal":{"name":"American Journal of Biomedical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Biomedical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/jbs.v10i1.57050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: TSH and circulating thyroid hormones are measured in serum as part of a thyroid function test (TFT), which evaluates the thyroid gland's ability to produce and regulate thyroid hormones. The objective of the current study was to compare the technical performance between ELISA, FEIA and the currently marketed automated CLIA for measuring the TSH level. Material and methods: A total of 1,200 participants were enrolled in the study. Subjects were chosen randomly, either OPD patients or inpatients of Birat Medical College Teaching Hospital. Chemiluminescence Immunoassay (CLIA), Enzyme-linked Immunoassay (ELISA) and Fluorometric Enzyme Immunoassay (FEIA) technologies were performed. Results: The total number of patients (1200) was categorized into group I, normal TSH (n = 680); group II, elevated TSH (n = 300); and group III, decreased TSH (n = 220). CLIA and FEIA based results were significantly more sensitive compared to ELISA results for TSH detection. Conclusion: Chemiluminescence assay system, when compared to FEIA and ELISA, is far superior in terms of accuracy and sensitivity for reporting both subnormal and above normal TSH levels and can be helpful in the detection of subclinical thyroid dysfunction (SCTD) and in the screening of thyroid diseases.
ELISA、FEIA和CLIA技术在促甲状腺激素诊断免疫分析中的比较分析:来自尼泊尔Morang的横断面研究
背景:TSH和循环甲状腺激素是作为甲状腺功能试验(TFT)的一部分在血清中测量的,该试验评估甲状腺产生和调节甲状腺激素的能力。本研究的目的是比较ELISA、FEIA和目前市场上销售的用于测量TSH水平的自动CLIA的技术性能。材料与方法:本研究共纳入1200名参与者。研究对象随机选取Birat医学院附属医院门诊患者和住院患者。采用化学发光免疫分析法(CLIA)、酶联免疫分析法(ELISA)和荧光酶免疫分析法(FEIA)技术。结果:1200例患者分为ⅰ组,TSH正常(n = 680);II组,TSH升高(n = 300);III组TSH降低(n = 220)。基于CLIA和FEIA的TSH检测结果明显高于ELISA检测结果。结论:与FEIA和ELISA相比,化学发光检测系统在报告TSH亚正常和高于正常水平方面的准确性和敏感性都远远优于FEIA和ELISA,可用于亚临床甲状腺功能障碍(SCTD)的检测和甲状腺疾病的筛查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信