Mass sensitive sensor, a comparative study between PVC and PEI coated on quartz crystal microbalance

K. Wong-ek, N. Nuntawong, K. Jaruwongrungsee, A. Tuantranont
{"title":"Mass sensitive sensor, a comparative study between PVC and PEI coated on quartz crystal microbalance","authors":"K. Wong-ek, N. Nuntawong, K. Jaruwongrungsee, A. Tuantranont","doi":"10.1109/INEC.2010.5424836","DOIUrl":null,"url":null,"abstract":"In this work, we report a comparative study of quartz crystal microbalance sensors for Cardiac marker detection. These sensors are deposited with two different polymers, polyvinylchroride (PVC) and polyethylenemine (PEI) using spray coating technique for preparation of adsorption surface. The AFM measurements show that the maximum RMS roughness of coated films occur at around 20 seconds of deposition time, under spraying pressure of 1 bar using precursors concentration of 1% w/v. The results indicate that PEI is far superior to PVC in term of surface roughness which is corresponding to the presence of micropores. The hydrophilic properties between these two materials confirm that PEI have a higher potentials of attracting bimolecular due to a lower contact angle to a droplet of DI water. The absorption of proteins A (103 molecules) suspension on PEI surface is verified by a SEM image.","PeriodicalId":6390,"journal":{"name":"2010 3rd International Nanoelectronics Conference (INEC)","volume":"9 1 1","pages":"1382-1383"},"PeriodicalIF":0.0000,"publicationDate":"2010-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 3rd International Nanoelectronics Conference (INEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INEC.2010.5424836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, we report a comparative study of quartz crystal microbalance sensors for Cardiac marker detection. These sensors are deposited with two different polymers, polyvinylchroride (PVC) and polyethylenemine (PEI) using spray coating technique for preparation of adsorption surface. The AFM measurements show that the maximum RMS roughness of coated films occur at around 20 seconds of deposition time, under spraying pressure of 1 bar using precursors concentration of 1% w/v. The results indicate that PEI is far superior to PVC in term of surface roughness which is corresponding to the presence of micropores. The hydrophilic properties between these two materials confirm that PEI have a higher potentials of attracting bimolecular due to a lower contact angle to a droplet of DI water. The absorption of proteins A (103 molecules) suspension on PEI surface is verified by a SEM image.
质量敏感传感器,在石英晶体微天平上涂覆PVC和PEI的比较研究
在这项工作中,我们报告了用于心脏标志物检测的石英晶体微平衡传感器的比较研究。这些传感器用两种不同的聚合物,聚氯乙烯(PVC)和聚乙烯胺(PEI)沉积,采用喷涂技术制备吸附表面。AFM测量结果表明,在1 bar的喷涂压力下,前驱体浓度为1% w/v,涂层的RMS粗糙度最大值出现在沉积时间约20秒时。结果表明,PEI在表面粗糙度方面远远优于PVC,这与微孔的存在相对应。这两种材料之间的亲水性证实了PEI具有更高的吸引双分子的潜力,因为它与一滴DI水的接触角较小。通过扫描电镜图像验证了蛋白A(103分子)悬浮液在PEI表面的吸附。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信