{"title":"Shielded enclosure accuracy improvements for MIL-STD-461E radiated emissions measurements","authors":"D. Warkentin, A. Wang, W. Crunkhorn","doi":"10.1109/ISEMC.2005.1513548","DOIUrl":null,"url":null,"abstract":"Radiated emissions measurements performed in accordance with MIL-STD-461E require the use of a shielded enclosure to prevent measurement contamination by ambient environmental signals. Unfortunately, these metallic enclosures add errors due to resonant effects. A simple test procedure, validated by finite difference time domain modeling, has been developed to characterize the HF response of a shielded enclosure. This procedure was used to improve the accuracy of a typical shielded enclosure while remaining compliant to the requirements of MIL-STD-461E.","PeriodicalId":6459,"journal":{"name":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","volume":"79 1","pages":"404-409 Vol. 2"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2005.1513548","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14
Abstract
Radiated emissions measurements performed in accordance with MIL-STD-461E require the use of a shielded enclosure to prevent measurement contamination by ambient environmental signals. Unfortunately, these metallic enclosures add errors due to resonant effects. A simple test procedure, validated by finite difference time domain modeling, has been developed to characterize the HF response of a shielded enclosure. This procedure was used to improve the accuracy of a typical shielded enclosure while remaining compliant to the requirements of MIL-STD-461E.