CdTe-DSD SPECT-I: An Ultrahigh-Resolution Multi-Isotope Tomographic Imager for Mice

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
S. Takeda, T. Orita, Atsushi Yagishita, M. Katsuragawa, G. Yabu, R. Tomaru, Fumiki Moriyama, Hirotaka Sugawara, Shin Watanabe, H. Mizuma, Y. Kanayama, K. Ohnuki, Hirofumi Fujii, L. Furenlid, Tadayuki Takahashi
{"title":"CdTe-DSD SPECT-I: An Ultrahigh-Resolution Multi-Isotope Tomographic Imager for Mice","authors":"S. Takeda, T. Orita, Atsushi Yagishita, M. Katsuragawa, G. Yabu, R. Tomaru, Fumiki Moriyama, Hirotaka Sugawara, Shin Watanabe, H. Mizuma, Y. Kanayama, K. Ohnuki, Hirofumi Fujii, L. Furenlid, Tadayuki Takahashi","doi":"10.1109/TRPMS.2023.3291756","DOIUrl":null,"url":null,"abstract":"Multi-isotope imaging in vivo is an appealing molecular imaging approach that provides extensive information about molecular pathways that cannot be accessed in usual imaging methods with a single radioactive probe. However, conventional imaging systems have limited energy resolution; as a result, the images obtained from multi-isotope imaging are associated with problems, such as nonnegligible noise and spectral crosstalk, owing to the photons emitted from radioisotopes being simultaneously used in the experiments. This study proposes a novel small-animal SPECT system, called CdTe-DSD SPECT-I, based on the cadmium telluride double-sided strip detector (CdTe-DSD), which was originally developed to observe high-energy X-rays and gamma rays in space. The detector has an energy resolution of 1–2 keV (FWHM) in 10–100 keV and 1.6% (FWHM) at 140 keV, which is approximately three times better than those of currently available high-grade semiconductor SPECT systems. Through imaging with phantoms, we demonstrate that the proposed system achieves an ultrahigh spatial resolution of over 0.35 mm for several radioisotopes. Furthermore, we demonstrate via animal experiments that the high-energy resolution and the crosstalk-subtraction method work effectively to suppress image noise and spectral crosstalk. We believe that the proposed system will allow investigators to choose various combinations of radioisotopes in their multi-isotope studies without much concern regarding potential spectral contaminations. Simultaneous visualization of drugs and probes distributed in small volumes in a mouse is possible with it.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRPMS.2023.3291756","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Multi-isotope imaging in vivo is an appealing molecular imaging approach that provides extensive information about molecular pathways that cannot be accessed in usual imaging methods with a single radioactive probe. However, conventional imaging systems have limited energy resolution; as a result, the images obtained from multi-isotope imaging are associated with problems, such as nonnegligible noise and spectral crosstalk, owing to the photons emitted from radioisotopes being simultaneously used in the experiments. This study proposes a novel small-animal SPECT system, called CdTe-DSD SPECT-I, based on the cadmium telluride double-sided strip detector (CdTe-DSD), which was originally developed to observe high-energy X-rays and gamma rays in space. The detector has an energy resolution of 1–2 keV (FWHM) in 10–100 keV and 1.6% (FWHM) at 140 keV, which is approximately three times better than those of currently available high-grade semiconductor SPECT systems. Through imaging with phantoms, we demonstrate that the proposed system achieves an ultrahigh spatial resolution of over 0.35 mm for several radioisotopes. Furthermore, we demonstrate via animal experiments that the high-energy resolution and the crosstalk-subtraction method work effectively to suppress image noise and spectral crosstalk. We believe that the proposed system will allow investigators to choose various combinations of radioisotopes in their multi-isotope studies without much concern regarding potential spectral contaminations. Simultaneous visualization of drugs and probes distributed in small volumes in a mouse is possible with it.
CdTe-DSD SPECT-I:用于小鼠的超高分辨率多同位素层析成像仪
体内多同位素成像是一种很有吸引力的分子成像方法,它提供了单个放射性探针无法获得的常规成像方法所不能获得的分子途径的广泛信息。然而,传统成像系统的能量分辨率有限;结果,由于实验中同时使用放射性同位素发射的光子,多同位素成像获得的图像存在不可忽略的噪声和光谱串扰等问题。本研究提出了一种新型的小动物SPECT系统,称为CdTe-DSD SPECT- i,该系统基于碲化镉双面条形探测器(CdTe-DSD),该探测器最初是为了在太空中观测高能x射线和伽马射线而开发的。该探测器在10-100 keV时的能量分辨率为1 - 2kev (FWHM),在140 keV时的能量分辨率为1.6% (FWHM),大约是目前可用的高级半导体SPECT系统的三倍。通过幻影成像,我们证明了所提出的系统对几种放射性同位素实现了超过0.35 mm的超高空间分辨率。此外,我们还通过动物实验证明了高能分辨率和串扰减法可以有效地抑制图像噪声和光谱串扰。我们相信,所提出的系统将允许研究人员在他们的多同位素研究中选择不同的放射性同位素组合,而不必担心潜在的光谱污染。同时可视化药物和探针分布在小体积的老鼠是可能的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信