Hydrodynamics and mass transfer inthree-phase airlift reactors for activated Carbon and sludge filtration

M. Salehi, Nasrin Hakimghiasi
{"title":"Hydrodynamics and mass transfer inthree-phase airlift reactors for activated Carbon and sludge filtration","authors":"M. Salehi, Nasrin Hakimghiasi","doi":"10.22104/AET.2017.454","DOIUrl":null,"url":null,"abstract":"A bioreactor refers to any manufactured or engineered device that supports a biologically active environment. These kinds of reactors are designed to treat wastewater treatment. Volumetric mass transfer coefficient and the effect of superficial gas velocity, as the most important operational factor on hydrodynamics, in three-phase airlift reactors are investigated in this study. The experiments for the external airlift reactor were carried out at a 0.14 downcomer to riser cross-sectional area ratio, and for the internal reactor at 0.36 and 1. Air and water were used as the gas and liquid phases, respectively, as well as activated carbon/sludge particles as the solid phase. Increasing the superficial gas velocity resulted in greater liquid circulation velocity, gas hold-up, and volumetric mass transfer coefficient; increasing the suspended activated carbon particles resulted in a decreased concentration of activated sludge, downcomer to riser cross sectional area ratio, liquid velocity, gas hold-up and volumetric mass transfer coefficient. The maximum gas hold-up was 0.178 which was attained in the external airlift reactor with a 1 Wt. % of activated sludge at a gas superficial velocity of 0.25 (m/s). The maximum volumetric mass transfer coefficient was 0.0485 (l/s) that was observed in the external airlift reactor containing activated carbon with a 0.00032 solid hold-up. A switch was observed in the activated sludge airlift reactor flow regime at gas velocities higher than 0.15 (m/s) and 0.18 (m/s) in the activated carbon airlift reactors.","PeriodicalId":7295,"journal":{"name":"Advances in environmental science and technology","volume":"40 1","pages":"179-184"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in environmental science and technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22104/AET.2017.454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A bioreactor refers to any manufactured or engineered device that supports a biologically active environment. These kinds of reactors are designed to treat wastewater treatment. Volumetric mass transfer coefficient and the effect of superficial gas velocity, as the most important operational factor on hydrodynamics, in three-phase airlift reactors are investigated in this study. The experiments for the external airlift reactor were carried out at a 0.14 downcomer to riser cross-sectional area ratio, and for the internal reactor at 0.36 and 1. Air and water were used as the gas and liquid phases, respectively, as well as activated carbon/sludge particles as the solid phase. Increasing the superficial gas velocity resulted in greater liquid circulation velocity, gas hold-up, and volumetric mass transfer coefficient; increasing the suspended activated carbon particles resulted in a decreased concentration of activated sludge, downcomer to riser cross sectional area ratio, liquid velocity, gas hold-up and volumetric mass transfer coefficient. The maximum gas hold-up was 0.178 which was attained in the external airlift reactor with a 1 Wt. % of activated sludge at a gas superficial velocity of 0.25 (m/s). The maximum volumetric mass transfer coefficient was 0.0485 (l/s) that was observed in the external airlift reactor containing activated carbon with a 0.00032 solid hold-up. A switch was observed in the activated sludge airlift reactor flow regime at gas velocities higher than 0.15 (m/s) and 0.18 (m/s) in the activated carbon airlift reactors.
三相气升式反应器用于活性炭和污泥过滤的流体力学和传质
生物反应器是指支持生物活性环境的任何制造或工程设备。这类反应器是设计用来处理废水的。研究了三相气升式反应器的体积传质系数和表面气速对流体力学的影响。外气升式反应器的降水管与提升管的截面积比分别为0.14和0.36。空气和水分别作为气相和液相,活性炭/污泥颗粒作为固相。增加表面气速,液体循环速度、气含率和体积传质系数增大;悬浮活性炭颗粒的增加导致活性污泥浓度、降水管截面积比、液速、气含率和体积传质系数的降低。最大气含率为0.178,在气表流速为0.25 (m/s)、活性污泥添加量为1wt . %的外部气升反应器中达到。在含0.00032固持率的外部气升式反应器中,观察到的最大体积传质系数为0.0485 (l/s)。在气速高于0.15 (m/s)和0.18 (m/s)的活性炭气速反应器中,观察到活性污泥气速反应器流动状态的切换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信