Estimation of Ultrasound Attenuation and its Application to Tissue Heterogeneity Study Using Nonlinear Least Square Data Fitting

Xiaoying Li, Dong Liu
{"title":"Estimation of Ultrasound Attenuation and its Application to Tissue Heterogeneity Study Using Nonlinear Least Square Data Fitting","authors":"Xiaoying Li, Dong Liu","doi":"10.1109/ICBBE.2009.5162800","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to provide a local attenuation method with applications to tissue heterogeneity estimation based on the peaks of ultrasound echo envelop data. To handle the frequency shift in the broadband ultrasound system, we use nonlinear least squares (NLS) data fitting directly to the local amplitude changes due to the tissue attenuation. By looking at the convergence of the NLS method, e.g., the Levenberg-Marquardt (LM) algorithm, we proposed a technique to test the tissue heterogeneity locally. System calibrations have been presented to compensate the aperture growth and beam diffraction effects. Algorithms have been verified both in phantom and in vivo images. Results showed that the proposed method can have 3.8% relative error in estimating attenuation coefficients of phantom images in a broadband system. It also showed the possible tissue heterogeneity from in vivo image.","PeriodicalId":6430,"journal":{"name":"2009 3rd International Conference on Bioinformatics and Biomedical Engineering","volume":"58 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 3rd International Conference on Bioinformatics and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBBE.2009.5162800","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The aim of this paper is to provide a local attenuation method with applications to tissue heterogeneity estimation based on the peaks of ultrasound echo envelop data. To handle the frequency shift in the broadband ultrasound system, we use nonlinear least squares (NLS) data fitting directly to the local amplitude changes due to the tissue attenuation. By looking at the convergence of the NLS method, e.g., the Levenberg-Marquardt (LM) algorithm, we proposed a technique to test the tissue heterogeneity locally. System calibrations have been presented to compensate the aperture growth and beam diffraction effects. Algorithms have been verified both in phantom and in vivo images. Results showed that the proposed method can have 3.8% relative error in estimating attenuation coefficients of phantom images in a broadband system. It also showed the possible tissue heterogeneity from in vivo image.
基于非线性最小二乘数据拟合的超声衰减估计及其在组织异质性研究中的应用
本文的目的是提供一种局部衰减方法,并应用于基于超声回波包络数据峰值的组织非均匀性估计。为了处理宽带超声系统中的频移问题,我们使用非线性最小二乘(NLS)数据直接拟合由组织衰减引起的局部振幅变化。通过观察NLS方法的收敛性,例如Levenberg-Marquardt (LM)算法,我们提出了一种局部检测组织异质性的技术。提出了补偿孔径增长和光束衍射效应的系统校准方法。算法已经在幻影和活体图像中得到验证。结果表明,该方法在宽带系统中估计虚像衰减系数的相对误差为3.8%。从活体图像也可以看出可能存在的组织异质性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信