{"title":"Analysis of Line Outage Detection in Nigeria 330kV Transmission Lines using Phasor Measurement Units","authors":"Nkem Francis Obodoagwu","doi":"10.37121/jase.v2i3.68","DOIUrl":null,"url":null,"abstract":"In this work, an analysis of line outage detection in Nigeria 330kV transmission lines using Phasor Measurement Units was presented. This requires collection and analysis of the data obtained from Transmission Company of Nigeria with the aid of PSAT 2.10.1 / MATLAB SIMULINK using Newton-Raphson power flow algorithm and also to determine the effectiveness of PMU when introduced in our power system network. 12 buses and 3 Generators system were considered for the studied. This was achieved by collecting relevant transmission parameters for 330kV line and was simulated on PSAT 2.10.1 and MATLAB 2015a using Newton-Raphson power flow algorithm. The work involved an offline and online analysis. For the offline analysis the admittance / impedance matrix for Y-bus and bus voltage for pre-outage was obtained via the power flow analysis and change in impedance for the lines were calculated. These values were further normalised in order to reduce the value to a row echelon form. Then for the online analysis; the change in phase angle from the Phasor Measurement Unit (PMU) online simulation for pre-outage and also post-outage was calculated and a normalised column matrix was gotten. Finally, the effectiveness of the line outage detection was graphically represented using MATLAB software to plot the values of the normalised values of the offline and online analysis; i.e., by comparing the normalised form of the offline and online values. These results clearly show that PMUs gives an accurate monitoring and total observability when introduced in Nigeria power system.","PeriodicalId":92218,"journal":{"name":"International journal of advances in science, engineering and technology","volume":"14 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of advances in science, engineering and technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37121/jase.v2i3.68","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, an analysis of line outage detection in Nigeria 330kV transmission lines using Phasor Measurement Units was presented. This requires collection and analysis of the data obtained from Transmission Company of Nigeria with the aid of PSAT 2.10.1 / MATLAB SIMULINK using Newton-Raphson power flow algorithm and also to determine the effectiveness of PMU when introduced in our power system network. 12 buses and 3 Generators system were considered for the studied. This was achieved by collecting relevant transmission parameters for 330kV line and was simulated on PSAT 2.10.1 and MATLAB 2015a using Newton-Raphson power flow algorithm. The work involved an offline and online analysis. For the offline analysis the admittance / impedance matrix for Y-bus and bus voltage for pre-outage was obtained via the power flow analysis and change in impedance for the lines were calculated. These values were further normalised in order to reduce the value to a row echelon form. Then for the online analysis; the change in phase angle from the Phasor Measurement Unit (PMU) online simulation for pre-outage and also post-outage was calculated and a normalised column matrix was gotten. Finally, the effectiveness of the line outage detection was graphically represented using MATLAB software to plot the values of the normalised values of the offline and online analysis; i.e., by comparing the normalised form of the offline and online values. These results clearly show that PMUs gives an accurate monitoring and total observability when introduced in Nigeria power system.
用相量测量装置检测尼日利亚330kV输电线路的停电分析
本文介绍了利用相量测量装置对尼日利亚330kV输电线路进行停电检测的分析。这就需要借助PSAT 2.10.1 / MATLAB SIMULINK使用牛顿-拉夫森潮流算法对尼日利亚输电公司获得的数据进行收集和分析,并确定PMU在我们的电力系统网络中引入的有效性。以12台母线和3台发电机系统为研究对象。通过采集330kV线路的相关输电参数,在PSAT 2.10.1和MATLAB 2015a上使用牛顿-拉夫森潮流算法进行仿真。这项工作包括离线和在线分析。在离线分析中,通过潮流分析得到了停机前y -母线的导纳/阻抗矩阵和母线电压,并计算了线路阻抗的变化。为了将这些值简化为行阶梯形,这些值进一步归一化。然后进行在线分析;计算了相量测量单元(PMU)在线仿真结果在断电前和断电后的相角变化,得到了归一化的列矩阵。最后,利用MATLAB软件将离线和在线分析的归一化值绘制成图形表示线路中断检测的有效性;即通过比较离线值和在线值的归一化形式。这些结果清楚地表明,在尼日利亚电力系统中引入pmu后,pmu提供了准确的监测和完全可观测性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信