{"title":"Electric stress analysis of a contaminated polymeric insulating surface in presence of dry bands","authors":"Arnab Das, D. K. Ghosh, R. Bose, S. Chatterjee","doi":"10.1109/ICICPI.2016.7859680","DOIUrl":null,"url":null,"abstract":"In this contribution, influence of dry bands on electric field distribution on a polymeric insulating surface has been carried out using Finite Element Method. Formation of dry bands on insulating surfaces result in electric field enhancement leading to surface discharges, dry-band arcing etc. which in turn affects the long term performance of the insulators. Hence, in the present work, a polymeric insulating surface is modeled as sheath model using Comsol Multiphysics software. Electric stress analysis is performed in presence of dry bands of different length and at different locations on a contaminated insulating surface. Moreover, the effect of different contamination levels on electric field distribution in presence of dry bands have also been investigated.","PeriodicalId":6501,"journal":{"name":"2016 International Conference on Intelligent Control Power and Instrumentation (ICICPI)","volume":"10 1","pages":"89-92"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Intelligent Control Power and Instrumentation (ICICPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICPI.2016.7859680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
In this contribution, influence of dry bands on electric field distribution on a polymeric insulating surface has been carried out using Finite Element Method. Formation of dry bands on insulating surfaces result in electric field enhancement leading to surface discharges, dry-band arcing etc. which in turn affects the long term performance of the insulators. Hence, in the present work, a polymeric insulating surface is modeled as sheath model using Comsol Multiphysics software. Electric stress analysis is performed in presence of dry bands of different length and at different locations on a contaminated insulating surface. Moreover, the effect of different contamination levels on electric field distribution in presence of dry bands have also been investigated.