A micro planar coil for local high resolution magnetic resonance imaging

H. Takahashi, T. Dohi, K. Matsumoto, I. Shimoyama
{"title":"A micro planar coil for local high resolution magnetic resonance imaging","authors":"H. Takahashi, T. Dohi, K. Matsumoto, I. Shimoyama","doi":"10.1109/MEMSYS.2007.4433156","DOIUrl":null,"url":null,"abstract":"This paper reports on a flexible micro planar coil for an MR (Magnetic Resonance) catheter. High resolution images can be obtained by using the MR catheter. Two types of coils of 5 mm and 20 mm in diameter were fabricated. Both of the coils were designed to have inductance of 1.0 muH at 8.5 MHz. The proto-type MR catheters were made by attaching the micro coils to the tip of acrylic pipes. In order to evaluate the MR catheters, the sensitive area and SNR (Signal to Noise Ratio) were measured. SNRs of the MR catheters were about three to eight times higher than that of a standard medical coil. Furthermore, we demonstrated that high resolution MR images can be achieved by using the MR catheters. MR images of a gumbo (Abelmoschus esculentus) were acquired with 0.5 x 0.5 x 1.0 mm3 resolution. While clear MR images were not able to be taken by the standard medical coil due to its low SNR, we were able to observe the gumbo and distinguished its seeds one by one in the MR images taken by the MR catheters.","PeriodicalId":6388,"journal":{"name":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"87 1","pages":"549-552"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2007.4433156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

This paper reports on a flexible micro planar coil for an MR (Magnetic Resonance) catheter. High resolution images can be obtained by using the MR catheter. Two types of coils of 5 mm and 20 mm in diameter were fabricated. Both of the coils were designed to have inductance of 1.0 muH at 8.5 MHz. The proto-type MR catheters were made by attaching the micro coils to the tip of acrylic pipes. In order to evaluate the MR catheters, the sensitive area and SNR (Signal to Noise Ratio) were measured. SNRs of the MR catheters were about three to eight times higher than that of a standard medical coil. Furthermore, we demonstrated that high resolution MR images can be achieved by using the MR catheters. MR images of a gumbo (Abelmoschus esculentus) were acquired with 0.5 x 0.5 x 1.0 mm3 resolution. While clear MR images were not able to be taken by the standard medical coil due to its low SNR, we were able to observe the gumbo and distinguished its seeds one by one in the MR images taken by the MR catheters.
用于局部高分辨率磁共振成像的微平面线圈
本文报道了一种用于磁共振导管的柔性微平面线圈。使用磁共振导管可以获得高分辨率的图像。制备了两种直径分别为5mm和20mm的线圈。这两个线圈设计为在8.5 MHz时具有1.0 muH的电感。通过将微线圈连接到丙烯酸管的尖端,制成了磁共振导管的原型。为了对磁共振导管进行评价,测量了导管的敏感面积和信噪比。磁共振导管的信噪比约为标准医用线圈的3至8倍。此外,我们证明了使用磁共振导管可以获得高分辨率的磁共振图像。获得秋葵(Abelmoschus esculentus)的MR图像,分辨率为0.5 x 0.5 x 1.0 mm3。由于标准医用线圈的低信噪比,无法拍摄清晰的MR图像,但我们能够在MR导管拍摄的MR图像中观察到秋葵,并逐一区分其种子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信