Clinical observation of endovascular thoracic aortic prosthetics in a patient with distal anastomosis aneurysm of a vascular prosthesis formed "end-to-side" after extraanatomic prosthetics

Q4 Medicine
N. Gorshkov, N. Chernaya, M. V. Parhomenko, R. Muslimov, V. S. Selyaev, L. Kokov
{"title":"Clinical observation of endovascular thoracic aortic prosthetics in a patient with distal anastomosis aneurysm of a vascular prosthesis formed \"end-to-side\" after extraanatomic prosthetics","authors":"N. Gorshkov, N. Chernaya, M. V. Parhomenko, R. Muslimov, V. S. Selyaev, L. Kokov","doi":"10.21688/1681-3472-2022-2-79-84","DOIUrl":null,"url":null,"abstract":"A clinical observation of successful prosthetics of an aneurysm of distal anastomosis of a vascular prosthesis of the thoracic aorta with a stent graft in a patient 24 years after extraanatomic bypass surgery with an end-to-side anastomosis for aortic coarctation is presented. During a routine examination, an aneurysm of the distal anastomosis of the vascular prosthesis was revealed in the patient. After further examination, thoracic aorta endoprosthesis was performed from vascular prosthesis to native aorta with Ankura 2020B120 stent graft (Lifetech Scientific Co., LTD. Shenzhen, China). Intraoperative results of endoprosthetics were assessed as good. The aneurysm of the distal anastomosis was not contrasted, the patency of the vessels of the aortic arch was preserved. According to the control computed tomography study performed 3 months after the operation, the aneurysm of the distal anastomosis is not contrasted, there is no dislocation of the prosthesis, there are no endolics. The above clinical observation demonstrates the effectiveness and safety of thoracic aortic endoprosthesis from a vascular prosthesis to a native aorta with anastomosis aneurysms of a vascular prosthesis, which allows avoiding complex and traumatic repeated open surgical intervention on the aorta and achieving good immediate and long-term treatment results.Received 25 November 2021. Revised 29 December 2021. Accepted 31 January 2022.Informed consent: The patient’s informed consent to use the records for medical purposes is obtained.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.Contribution of the authors Literature review: N.S. Gorshkov. Drafting the article: N.S. Gorshkov, N.R. ChernayaCritical revision of the article: R.Sh. Muslimov, L.S. KokovSurgical treatment: N.S. Gorshkov, N.R. Chernaya, M.V. Parhomenko, V.S. SelyaevFinal approval of the version to be published: N.S. Gorshkov, N.R. Chernaya, M.V. Parhomenko, V.S. Selyaev, L.S. Kokov","PeriodicalId":19853,"journal":{"name":"Patologiya krovoobrashcheniya i kardiokhirurgiya","volume":"74 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patologiya krovoobrashcheniya i kardiokhirurgiya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21688/1681-3472-2022-2-79-84","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

A clinical observation of successful prosthetics of an aneurysm of distal anastomosis of a vascular prosthesis of the thoracic aorta with a stent graft in a patient 24 years after extraanatomic bypass surgery with an end-to-side anastomosis for aortic coarctation is presented. During a routine examination, an aneurysm of the distal anastomosis of the vascular prosthesis was revealed in the patient. After further examination, thoracic aorta endoprosthesis was performed from vascular prosthesis to native aorta with Ankura 2020B120 stent graft (Lifetech Scientific Co., LTD. Shenzhen, China). Intraoperative results of endoprosthetics were assessed as good. The aneurysm of the distal anastomosis was not contrasted, the patency of the vessels of the aortic arch was preserved. According to the control computed tomography study performed 3 months after the operation, the aneurysm of the distal anastomosis is not contrasted, there is no dislocation of the prosthesis, there are no endolics. The above clinical observation demonstrates the effectiveness and safety of thoracic aortic endoprosthesis from a vascular prosthesis to a native aorta with anastomosis aneurysms of a vascular prosthesis, which allows avoiding complex and traumatic repeated open surgical intervention on the aorta and achieving good immediate and long-term treatment results.Received 25 November 2021. Revised 29 December 2021. Accepted 31 January 2022.Informed consent: The patient’s informed consent to use the records for medical purposes is obtained.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.Contribution of the authors Literature review: N.S. Gorshkov. Drafting the article: N.S. Gorshkov, N.R. ChernayaCritical revision of the article: R.Sh. Muslimov, L.S. KokovSurgical treatment: N.S. Gorshkov, N.R. Chernaya, M.V. Parhomenko, V.S. SelyaevFinal approval of the version to be published: N.S. Gorshkov, N.R. Chernaya, M.V. Parhomenko, V.S. Selyaev, L.S. Kokov
胸主动脉血管内修复术治疗经解剖外修复术后端侧吻合动脉瘤的一例临床观察
本文报道一例腹主动脉端侧吻合术后24年胸主动脉端侧搭桥手术成功修复远端动脉瘤的临床观察。在例行检查中,发现患者血管假体远端吻合处有动脉瘤。经进一步检查后,采用Ankura 2020B120支架(Lifetech Scientific Co., LTD.)从血管假体到原生主动脉进行胸主动脉内假体。深圳,中国)。术中结果评价为良好。远端吻合动脉瘤未作对比,保留主动脉弓血管的通畅。根据术后3个月进行的对照计算机断层研究,远端吻合口动脉瘤未对比,假体无脱位,无内陷。以上临床观察证明了由血管假体到血管假体吻合动脉瘤的天然主动脉内假体的有效性和安全性,避免了对主动脉的复杂和创伤性的重复开放手术干预,取得了良好的即时和长期治疗效果。收到2021年11月25日。2021年12月29日修订。接受日期为2022年1月31日。知情同意:已取得患者知情同意将病历用于医疗目的。经费来源:本研究未获得赞助。利益冲突:作者声明无利益冲突。文献综述:N.S. Gorshkov。文章起草:N.S. Gorshkov, N.R. chernay文章关键修改:R.Sh。手术治疗:N.S. Gorshkov, N.R. Chernaya, M.V. Parhomenko, V.S. selyav最终批准出版版本:N.S. Gorshkov, N.R. Chernaya, M.V. Parhomenko, V.S. Selyaev, L.S. Kokov
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Patologiya krovoobrashcheniya i kardiokhirurgiya
Patologiya krovoobrashcheniya i kardiokhirurgiya Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.00
自引率
0.00%
发文量
42
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信