A Downhole Wireline Module for the Measurement of Bubble Point Pressure

M. Rashaid, C. Harrison, H. Ayyad, H. Dumont, E. Smythe, M. Sullivan, J. Meier, Shunsuke Fukagawa, Masaki Miyashita, B. Grant, Y. Morikami, Y. Kajikawa, Y. Maekawa, H. Tsuboi
{"title":"A Downhole Wireline Module for the Measurement of Bubble Point Pressure","authors":"M. Rashaid, C. Harrison, H. Ayyad, H. Dumont, E. Smythe, M. Sullivan, J. Meier, Shunsuke Fukagawa, Masaki Miyashita, B. Grant, Y. Morikami, Y. Kajikawa, Y. Maekawa, H. Tsuboi","doi":"10.2118/197927-ms","DOIUrl":null,"url":null,"abstract":"\n The accuracy of the phase envelope calculated for a black oil sample strongly depends upon the quality and type of information used to optimize the equation of state (EOS). Possible inputs for EOS tuning include (but is not limited to) composition from a chromatogram or optical absorbance, density, saturation pressure (bubble or dew point pressure), and the relative volumes of liquid and gas. In this manuscript, we describe a workflow using a system of microsensors that our group has previously published that accurately measures fluid properties from which the phase envelopes of several black oil samples are calculated and refined.","PeriodicalId":11328,"journal":{"name":"Day 4 Thu, November 14, 2019","volume":"13 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 4 Thu, November 14, 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/197927-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The accuracy of the phase envelope calculated for a black oil sample strongly depends upon the quality and type of information used to optimize the equation of state (EOS). Possible inputs for EOS tuning include (but is not limited to) composition from a chromatogram or optical absorbance, density, saturation pressure (bubble or dew point pressure), and the relative volumes of liquid and gas. In this manuscript, we describe a workflow using a system of microsensors that our group has previously published that accurately measures fluid properties from which the phase envelopes of several black oil samples are calculated and refined.
用于泡点压力测量的井下电缆模块
黑油样品相包络线计算的准确性很大程度上取决于用于优化状态方程(EOS)的信息的质量和类型。EOS调谐的可能输入包括(但不限于)色谱图或光学吸光度的成分、密度、饱和压力(气泡或露点压力)以及液体和气体的相对体积。在这篇手稿中,我们描述了一个使用微传感器系统的工作流程,该系统是我们小组之前发表的,可以精确测量流体特性,从中计算和精炼几种黑油样品的相包络。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信