Electrical simulations of series and parallel PV arc-faults

J. Flicker, Jay Johnson
{"title":"Electrical simulations of series and parallel PV arc-faults","authors":"J. Flicker, Jay Johnson","doi":"10.1109/PVSC.2013.6745127","DOIUrl":null,"url":null,"abstract":"Arcing in PV systems has caused multiple residential and commercial rooftop fires. The National Electrical Code® (NEC) added section 690.11 to mitigate this danger by requiring arc-fault circuit interrupters (AFCI). Currently, the requirement is only for series arc-faults, but to fully protect PV installations from arc-fault-generated fires, parallel arc-faults must also be mitigated effectively. In order to de-energize a parallel arc-fault without module-level disconnects, the type of arc-fault must be identified so that proper action can be taken (e.g., opening the array for a series arc-fault and shorting for a parallel arc-fault). In this work, we investigate the electrical behavior of the PV system during series and parallel arc-faults to (a) understand the arcing power available from different faults, (b) identify electrical characteristics that differentiate the two fault types, and (c) determine the location of the fault based on current or voltage of the faulted array. This information can be used to improve arc-fault detector speed and functionality.","PeriodicalId":6350,"journal":{"name":"2013 IEEE 39th Photovoltaic Specialists Conference (PVSC)","volume":"28 1","pages":"3165-3172"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 39th Photovoltaic Specialists Conference (PVSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVSC.2013.6745127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 47

Abstract

Arcing in PV systems has caused multiple residential and commercial rooftop fires. The National Electrical Code® (NEC) added section 690.11 to mitigate this danger by requiring arc-fault circuit interrupters (AFCI). Currently, the requirement is only for series arc-faults, but to fully protect PV installations from arc-fault-generated fires, parallel arc-faults must also be mitigated effectively. In order to de-energize a parallel arc-fault without module-level disconnects, the type of arc-fault must be identified so that proper action can be taken (e.g., opening the array for a series arc-fault and shorting for a parallel arc-fault). In this work, we investigate the electrical behavior of the PV system during series and parallel arc-faults to (a) understand the arcing power available from different faults, (b) identify electrical characteristics that differentiate the two fault types, and (c) determine the location of the fault based on current or voltage of the faulted array. This information can be used to improve arc-fault detector speed and functionality.
串联和并联PV电弧故障的电气模拟
光伏系统中的电弧已经引起了多起住宅和商业屋顶火灾。国家电气规范(NEC)增加了第690.11节,通过要求电弧故障断路器(AFCI)来减轻这种危险。目前,这一要求仅针对串联电弧故障,但为了充分保护光伏装置免受电弧故障引发的火灾的影响,并联电弧故障也必须得到有效缓解。为了在不引起模块级断线的情况下使并联电弧故障断电,必须确定电弧故障的类型,以便采取适当的措施(例如,对串联电弧故障打开阵列,对并联电弧故障进行短路)。在这项工作中,我们研究了PV系统在串联和并联电弧故障期间的电气行为,以(a)了解不同故障产生的电弧功率,(b)识别区分两种故障类型的电气特征,以及(c)根据故障阵列的电流或电压确定故障位置。这些信息可用于提高电弧故障检测器的速度和功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信