{"title":"PENETAPAN KADAR METANOL HASIL DESTILASI PENGUAP VAKUM PUTAR EKSTRAK METANOL DAUN UBI UNGU MENGGUNAKAN RAMAN SPEKTROFOTOMETER","authors":"Santika Dewi","doi":"10.24843/jfu.2018.v07.i01.p03","DOIUrl":null,"url":null,"abstract":"Solvent extracted results are often not utilized for re-extraction. Methanol is a universal solvent which is often used as an extract of simplicia. The result of a rotary vacuum evaporator distillation is not known purity and level. Raman spectrosphotometer is a non destructive method of analysis that can be applied to determine the levels and purity of distilled methanol. The objective of this research is to know the change of vacuum pressure to the level and purity of methanol, so that methanol from rotary vacuum distillation can be reused for re-extraction. Purple sweet potato leaves are macerated using 95% methanol : 3% citric acid. The extract was evaporated using a rotary vacuum evaporator at 100 mbar, 150 mbar, and 200 mbar vacuum pressure with a range of 5 to 180 min. Purity and methanol levels were determined using a Raman Handheld 1064 nm spectrophotometer. \nValidation of methanol assay method with Raman spectrophotometer was obtained: precision: KV 0.19% -1.70%, accuracy: 94.4-103.8%, limit of detection: 1.77% (v/v), limit of quantification: 5.89% (v/v), the range of linearity of 1.77% -99.9% (v/v), with a calibration curve equation: y = 216,88x + 1437.1 and the value of R2 = 0.9997. Methanol content of distillation product with pressure variation 100 - 200 mbar in the span of 5 to 180 minutes obtained methanol level 59.8-81.2% (v/v). All distilled methanol yields a spectrum similarity of 86-99% when compared with absolute methanol.","PeriodicalId":17752,"journal":{"name":"Jurnal Farmasi Udayana","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Farmasi Udayana","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24843/jfu.2018.v07.i01.p03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Solvent extracted results are often not utilized for re-extraction. Methanol is a universal solvent which is often used as an extract of simplicia. The result of a rotary vacuum evaporator distillation is not known purity and level. Raman spectrosphotometer is a non destructive method of analysis that can be applied to determine the levels and purity of distilled methanol. The objective of this research is to know the change of vacuum pressure to the level and purity of methanol, so that methanol from rotary vacuum distillation can be reused for re-extraction. Purple sweet potato leaves are macerated using 95% methanol : 3% citric acid. The extract was evaporated using a rotary vacuum evaporator at 100 mbar, 150 mbar, and 200 mbar vacuum pressure with a range of 5 to 180 min. Purity and methanol levels were determined using a Raman Handheld 1064 nm spectrophotometer. Validation of methanol assay method with Raman spectrophotometer was obtained: precision: KV 0.19% -1.70%, accuracy: 94.4-103.8%, limit of detection: 1.77% (v/v), limit of quantification: 5.89% (v/v), the range of linearity of 1.77% -99.9% (v/v), with a calibration curve equation: y = 216,88x + 1437.1 and the value of R2 = 0.9997. Methanol content of distillation product with pressure variation 100 - 200 mbar in the span of 5 to 180 minutes obtained methanol level 59.8-81.2% (v/v). All distilled methanol yields a spectrum similarity of 86-99% when compared with absolute methanol.
利用光谱仪对甲醇的影响
溶剂提取的结果通常不用于再提取。甲醇是一种通用的溶剂,常被用作单纯草的提取物。旋转真空蒸发器蒸馏的结果是未知的纯度和水平。拉曼分光光度计是一种非破坏性的分析方法,可用于测定蒸馏甲醇的水平和纯度。本研究的目的是了解真空压力对甲醇的液位和纯度的变化,以便旋转真空蒸馏的甲醇可以重复使用进行再萃取。紫薯叶浸渍使用95%甲醇:3%柠檬酸。提取液使用旋转真空蒸发器在100 mbar, 150 mbar和200 mbar真空压力下蒸发5至180分钟。纯度和甲醇水平使用拉曼手持式1064 nm分光光度计测定。用拉曼分光光度计对甲醇分析方法进行验证,得到精密度:KV 0.19% ~ 1.70%,准确度:94.4 ~ 103.8%,检出限:1.77% (v/v),定量限:5.89% (v/v),线性范围为1.77% ~ 99.9% (v/v),标定曲线方程:y = 216,88x + 1437.1, R2 = 0.9997。在压力变化为100 ~ 200mbar的5 ~ 180分钟内,蒸馏产物甲醇含量为59.8 ~ 81.2% (v/v)。与绝对甲醇相比,所有蒸馏甲醇的光谱相似性为86-99%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信