S. G. Dastider, Syed Barizuddin, Yifan Wu, M. Dweik, M. Almasri
{"title":"Impedance biosensor based on interdigitated electrode arrays for detection of low levels of E.coli O157:H7","authors":"S. G. Dastider, Syed Barizuddin, Yifan Wu, M. Dweik, M. Almasri","doi":"10.1109/MEMSYS.2013.6474404","DOIUrl":null,"url":null,"abstract":"We report an interdigitated electrode array (IDEA) impedance biosensor with rapid detection of Escherichia coli O157:H7. This biosensor has significantly better detection capability compared with the conventional microbiological testing method. The total detection time for this biosensor is under 3 hours. Dielectrophoresis (DEP) is used in conjunction with impedance spectroscopy to improve the detection capability of the biosensor. The IDEA surface is functionalized using anti-E.coli antibody for selectivity of the bacteria. The dose response was in-between 3 × 106 CFU/mL and 3 × 102 CFU/mL. This is 10 fold better than the detection limit previously reported using impedance based biosensors.","PeriodicalId":92162,"journal":{"name":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","volume":"15 1","pages":"955-958"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2013.6474404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
We report an interdigitated electrode array (IDEA) impedance biosensor with rapid detection of Escherichia coli O157:H7. This biosensor has significantly better detection capability compared with the conventional microbiological testing method. The total detection time for this biosensor is under 3 hours. Dielectrophoresis (DEP) is used in conjunction with impedance spectroscopy to improve the detection capability of the biosensor. The IDEA surface is functionalized using anti-E.coli antibody for selectivity of the bacteria. The dose response was in-between 3 × 106 CFU/mL and 3 × 102 CFU/mL. This is 10 fold better than the detection limit previously reported using impedance based biosensors.