Automated on-line liquid-liquid extraction in a multisyringe flow injection analysis manifold for migration studies in food-contact materials: analysis of 4,4´-dihydroxybiphenyl
I. Delgado-Blanca, E. Llorent-Martínez, A. Ruiz-Medina, Ortega-Barrales Pilar
{"title":"Automated on-line liquid-liquid extraction in a multisyringe flow injection analysis manifold for migration studies in food-contact materials: analysis of 4,4´-dihydroxybiphenyl","authors":"I. Delgado-Blanca, E. Llorent-Martínez, A. Ruiz-Medina, Ortega-Barrales Pilar","doi":"10.1080/19440049.2019.1678769","DOIUrl":null,"url":null,"abstract":"ABSTRACT Packaging may represent a source of food contamination, as different organic compounds and degradation compounds may migrate from packaging to foodstuff. For fatty foods, rectified olive oil is the common simulant, which implies time-consuming and laborious liquid-liquid extraction (LLE) procedures to isolate the contaminant(s) from the oil. Here we propose a Multisyringe Flow Injection Analysis manifold to automate this sample treatment, using the monomer 4,4´-dihydroxybiphenyl as the contaminant. The LLE procedure, using water as extractant, was fully automated. After the on-line LLE, the resulting extract was pumped through a fluorescence detector, inside which a flow-cell filled with C18 silica gel solid support was placed. The analyte was pre-concentrated on the solid support (in which the analytical signal was directly recorded), so improving the sensitivity of the system. Under optimum conditions, the method detection limit is 0.05 mg kg−1, well within the specific migration limit of 6 mg kg−1. The method developed was compared with the standard CEN test method (off-line LLE and HPLC determination) observing savings in sample and reagents of 90% and a 7-fold increase in sample throughput. Graphical abstract","PeriodicalId":12121,"journal":{"name":"Food Additives & Contaminants: Part A","volume":"9 1","pages":"174 - 182"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Additives & Contaminants: Part A","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19440049.2019.1678769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
ABSTRACT Packaging may represent a source of food contamination, as different organic compounds and degradation compounds may migrate from packaging to foodstuff. For fatty foods, rectified olive oil is the common simulant, which implies time-consuming and laborious liquid-liquid extraction (LLE) procedures to isolate the contaminant(s) from the oil. Here we propose a Multisyringe Flow Injection Analysis manifold to automate this sample treatment, using the monomer 4,4´-dihydroxybiphenyl as the contaminant. The LLE procedure, using water as extractant, was fully automated. After the on-line LLE, the resulting extract was pumped through a fluorescence detector, inside which a flow-cell filled with C18 silica gel solid support was placed. The analyte was pre-concentrated on the solid support (in which the analytical signal was directly recorded), so improving the sensitivity of the system. Under optimum conditions, the method detection limit is 0.05 mg kg−1, well within the specific migration limit of 6 mg kg−1. The method developed was compared with the standard CEN test method (off-line LLE and HPLC determination) observing savings in sample and reagents of 90% and a 7-fold increase in sample throughput. Graphical abstract
包装可能是食品污染源之一,因为不同的有机化合物和降解化合物可能从包装转移到食品中。对于高脂肪食品,精炼橄榄油是常见的模拟物,这意味着耗时且费力的液-液萃取(LLE)程序来从油中分离污染物。在这里,我们提出了一个多注射器流动注射分析歧管自动化样品处理,使用单体4,4´-二羟基联苯作为污染物。LLE过程以水为萃取剂,完全自动化。在线LLE后,将得到的提取物通过荧光检测器泵送,在荧光检测器内放置充满C18硅胶固体载体的流动池。分析物被预先浓缩在固体载体上(在固体载体上直接记录分析信号),从而提高了系统的灵敏度。在最佳条件下,该方法的检出限为0.05 mg kg - 1,完全在6 mg kg - 1的特定迁移限内。将该方法与标准的CEN测试方法(离线LLE和HPLC测定)进行比较,发现样品和试剂节省90%,样品通量提高7倍。图形抽象