Effects of color filters and anti-reflective coating on contrast sensitivity under glare condition

M. Mahjoob, S. Heydarian
{"title":"Effects of color filters and anti-reflective coating on contrast sensitivity under glare condition","authors":"M. Mahjoob, S. Heydarian","doi":"10.34172/jrcm.2020.028","DOIUrl":null,"url":null,"abstract":"Background: Since light scattering has a great impact on visual performances, this study was conducted to compare the effects of color filters and anti-reflective coating on contrast sensitivity (CS) in normal people under glare condition. Methods: This semi-experimental study was conducted on 40 medical students (aged 19- 25 years). Ophthalmologic tests including visual acuity and refractive error measurement, biomicroscopy, fundoscopy, and CS assessment were conducted for all participants. CS was determined using Pelli-Robson chart at a distance of one meter. To measure the effect of glare on CS, we used an additional lighting source (60 W tungsten filament incandescent lamp) in the patient’s visual field. Thus, at an intensity of 2000 lux, the light source was placed at a distance of 18.5 cm from the patient’s eye in a way that it was 10 degrees above the subject’s visual axis. Monocular CS measurements were performed with and without glare. Monocular CS was evaluated again under glare conditions with the yellow and pink filters, with the transmission rate of 85%, and anti-reflective coating. Results: The mean log CS of subjects under glare (1.48±0.09) was lower than that in the absence of glare (1.71±0.09) (<0.001); moreover, repeated measures ANOVA showed the yellow filter (1.48±0.10), pink filter (1.47±0.10), and anti-reflective coating (1.47±0.09) had no significant impact on improving visual performance under glare condition (P=0.471). Conclusion: Colored filters and anti-reflective coatings are not effective in enhancing the vision of young normal individuals under glare conditions and at low spatial frequencies.","PeriodicalId":17071,"journal":{"name":"Journal of Research in Clinical Medicine","volume":"21 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research in Clinical Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/jrcm.2020.028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Since light scattering has a great impact on visual performances, this study was conducted to compare the effects of color filters and anti-reflective coating on contrast sensitivity (CS) in normal people under glare condition. Methods: This semi-experimental study was conducted on 40 medical students (aged 19- 25 years). Ophthalmologic tests including visual acuity and refractive error measurement, biomicroscopy, fundoscopy, and CS assessment were conducted for all participants. CS was determined using Pelli-Robson chart at a distance of one meter. To measure the effect of glare on CS, we used an additional lighting source (60 W tungsten filament incandescent lamp) in the patient’s visual field. Thus, at an intensity of 2000 lux, the light source was placed at a distance of 18.5 cm from the patient’s eye in a way that it was 10 degrees above the subject’s visual axis. Monocular CS measurements were performed with and without glare. Monocular CS was evaluated again under glare conditions with the yellow and pink filters, with the transmission rate of 85%, and anti-reflective coating. Results: The mean log CS of subjects under glare (1.48±0.09) was lower than that in the absence of glare (1.71±0.09) (<0.001); moreover, repeated measures ANOVA showed the yellow filter (1.48±0.10), pink filter (1.47±0.10), and anti-reflective coating (1.47±0.09) had no significant impact on improving visual performance under glare condition (P=0.471). Conclusion: Colored filters and anti-reflective coatings are not effective in enhancing the vision of young normal individuals under glare conditions and at low spatial frequencies.
滤色片和增透膜对眩光条件下对比灵敏度的影响
背景:由于光散射对视觉性能的影响很大,本研究比较了在眩光条件下,滤色片和抗反射涂层对正常人对比敏感度(CS)的影响。方法:对40名年龄在19 ~ 25岁的医学生进行半实验研究。对所有参与者进行眼科检查,包括视力和屈光不正测量、生物显微镜、眼底镜检查和CS评估。用Pelli-Robson图在1米距离处测定CS。为了测量眩光对CS的影响,我们在患者的视野中使用了一个额外的光源(60 W钨丝白炽灯)。因此,在2000勒克斯的强度下,光源被放置在距离患者眼睛18.5厘米的地方,在受试者视觉轴上方10度。在有眩光和没有眩光的情况下进行单目CS测量。在强光条件下,使用黄色和粉色滤光片再次评估单眼CS,透射率为85%,并涂有抗反射涂层。结果:强光条件下受试者的平均对数CS(1.48±0.09)低于无强光条件下受试者的平均对数CS(1.71±0.09)(<0.001);此外,重复测量方差分析显示,黄色滤光片(1.48±0.10)、粉红色滤光片(1.47±0.10)和抗反射涂层(1.47±0.09)对眩光条件下视觉性能的改善没有显著影响(P=0.471)。结论:有色滤光片和增透膜在强光条件下和低空间频率下不能有效地增强年轻正常人的视力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信