Ultratrace-level determination of N-Nitrosodimethylamine, N-Nitrosodiethylamine, and N-Nitrosomorpholine in waters by solid-phase extraction followed by liquid chromatography-tandem mass spectrometry

Y. Kadmi, L. Favier, I. Soutrel, M. Lemasle, D. Wolbert
{"title":"Ultratrace-level determination of N-Nitrosodimethylamine, N-Nitrosodiethylamine, and N-Nitrosomorpholine in waters by solid-phase extraction followed by liquid chromatography-tandem mass spectrometry","authors":"Y. Kadmi, L. Favier, I. Soutrel, M. Lemasle, D. Wolbert","doi":"10.2478/s11532-014-0537-z","DOIUrl":null,"url":null,"abstract":"N-nitrosamines are a new class of emerging nitrogenous drinking water disinfection by-products. These compounds are probably carcinogenic which could seriously affect the safety of drinking water consumers. The aim of this study is to develop a simple, fast, and specific analytical method for the routine determination of low part per trillion levels of N-nitrosamines in waters. An ultra high pressure liquid chromatography coupled with tandem mass spectrometry (UHPLC/MS/MS) method was developed for the qualitative and quantitative analysis of N-nitrosamines in waters. N-nitrosamines were extracted, purified and concentrated from water samples in one step using a solid-phase extraction (SPE). The compounds were detected in multiple reaction monitoring via electrospray ionisation source with positive ionisation mode. To achieve symmetrical peak shapes and a short chromatographic analysis time, the mobile phase consisting of acetonitrile, water and formic acid (60:40:0.1, v/v/v) was used in the experiment. Chromatographic separation of N-nitrosamines was done in less than two minutes. All calibration curves had good linearity (r2≥ 0.9989). The intra- and inter-day precision of the assay ranged from 0.59% to 3.11% and accuracy ranged from 99.66% to 104.1%. The mean recoveries of N-nitrosamines in spiked water were 98%-101%. The reproducability was acceptable with relative standard deviations of less than 3.53%. The proposed method yielded detection limits very low which ranges from 0.04 to 0.16 ng L−1. Finally, the developed analytical method was successfully applied to the analysis of N-nitrosamines in natural water sample","PeriodicalId":9888,"journal":{"name":"Central European Journal of Chemistry","volume":"18 1","pages":"928-936"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Central European Journal of Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/s11532-014-0537-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

N-nitrosamines are a new class of emerging nitrogenous drinking water disinfection by-products. These compounds are probably carcinogenic which could seriously affect the safety of drinking water consumers. The aim of this study is to develop a simple, fast, and specific analytical method for the routine determination of low part per trillion levels of N-nitrosamines in waters. An ultra high pressure liquid chromatography coupled with tandem mass spectrometry (UHPLC/MS/MS) method was developed for the qualitative and quantitative analysis of N-nitrosamines in waters. N-nitrosamines were extracted, purified and concentrated from water samples in one step using a solid-phase extraction (SPE). The compounds were detected in multiple reaction monitoring via electrospray ionisation source with positive ionisation mode. To achieve symmetrical peak shapes and a short chromatographic analysis time, the mobile phase consisting of acetonitrile, water and formic acid (60:40:0.1, v/v/v) was used in the experiment. Chromatographic separation of N-nitrosamines was done in less than two minutes. All calibration curves had good linearity (r2≥ 0.9989). The intra- and inter-day precision of the assay ranged from 0.59% to 3.11% and accuracy ranged from 99.66% to 104.1%. The mean recoveries of N-nitrosamines in spiked water were 98%-101%. The reproducability was acceptable with relative standard deviations of less than 3.53%. The proposed method yielded detection limits very low which ranges from 0.04 to 0.16 ng L−1. Finally, the developed analytical method was successfully applied to the analysis of N-nitrosamines in natural water sample
固相萃取-液相色谱-串联质谱法测定水中n -亚硝基二甲胺、n -亚硝基二乙胺和n -亚硝基somorpholine
n -亚硝胺是一类新兴的含氮饮用水消毒副产物。这些化合物可能具有致癌性,会严重影响饮用水消费者的安全。本研究的目的是建立一种简单、快速、特异的分析方法,用于常规测定水中低万亿分之一水平的n -亚硝胺。建立了超高压液相色谱-串联质谱法(UHPLC/MS/MS)对水体中n -亚硝胺进行定性和定量分析的方法。采用固相萃取法(SPE)一步提取、纯化和浓缩水样中的n -亚硝胺。采用电喷雾电离源,采用正电离模式对化合物进行多反应监测。为了达到峰形对称和色谱分析时间短,实验采用乙腈、水和甲酸(60:40:1 . 0,v/v/v)为流动相。n -亚硝胺的色谱分离在不到两分钟的时间内完成。所有校准曲线线性良好(r2≥0.9989)。日内、日间精密度为0.59% ~ 3.11%,准确度为99.66% ~ 104.1%。n -亚硝胺在加样水中的平均回收率为98% ~ 101%。重现性可接受,相对标准偏差小于3.53%。该方法的检测限非常低,范围为0.04至0.16 ng L−1。最后,将所建立的分析方法成功地应用于天然水样中n -亚硝胺的分析
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
3 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信